19 May 2022
Nova Mooar House, The Cronk, Ballaugh, Isle Of Man, IM7 5ba
Click a button above to find applications similar to this one.
See how this application compares to similar ones — policies, conditions, and outcomes side by side.
Highways Development Control objects to the retrospective vehicular access due to failure to meet design criteria in the Manual for Manx Roads and requests additional information including visibility splay and access drawings.
Key concern: does not meet Manual for Manx Roads design criteria including entry splays, surface material, gate setback, and visibility splays
Department of Infrastructure Highways Development Control
Conditional No ObjectionThe creation of a direct access onto the highway has specific design criteria, which can be found in Manual for Manx Roads.; From the photographs provided, the access appears to meet the minimum width requirement. However, all other criteria have not been met.; Highway Services request the following revisions/additional information to be provided: A visibility splay drawing showing the achievable visibility from a 2.4m setback distance; An access drawing showing the width of the access proposed, with appropriate entry splays, a bound and consolidated surface and gates setback 6m from the highway.; Recommendation: Request additional information/revisions.
Conditions requested: Section 109(A) Highway Agreement to be completed post planning consent; provide run off / surface water drainage to prevent water flowing onto or damaging public road; retain existing road drainage or provide effective alternative at Applicant’s expense agreed with Highway Services’ Drainage team