Loading document...
==== PAGE 1 ====
KITCHEN DINING LOUNGE WC PROPOSED SUN LOUNGE 3625 150 325 4305 1500 100mm HALF ROUND PVCU RW GUTTER CONSERVATORY INSULATED ROOF SYSTEM WITH TILE FINISH FIXED IN ACCORDANCE WITH MANUFACTURES DETAILS LEAN MIX CONCRETE CAVITY FILL UPTO 225mm BELOW DPC LEVEL 750x200mm CONCRETE STRIP FOUNDATION DPC MIN 150mm ABOVE FINISHED GROUND LEVEL PROVIDE WEEP HOLES AT GROUND LEVEL AT 900mm c/cs 100x50mm TREATED SW WALL PLATE STRAPPED DOWN TO WALL AT 1200mm c/cs WITH 1350x30x5mm GALV STEEL STRAPS ROCKWOOL CAVITY CLOSER 600 PRECAST CONCRETE SUB CILL TO MATCH EXISTING BEDDED ON DPC 2617 LINE OF BOUNDARY DRAWING No DRAWING PROJECT 02 Proposed Sun Lounge 9 Birch Drive Ballawattleworth Estate Peel IM5 1WR Proposed REV DATE 04.04.21 SCALE AS NOTED @ A1 PROPOSED GROUND FLOOR PLAN 1:50 PROPOSED NORTH ELEVATION 1:100 PROPOSED WEST ELEVATION 1:100 PROPOSED EAST ELEVATION 1:100 TYPICAL SECTION 1:50 NOTES 325mm CAVITY WALL EXTERNAL LEAF S/C RENDER ON 7N 100mm DENSE CONCRETE BLOCKWORK / 125mm CAVITY WITH 75mm ECOTHERM INSULATION OR SIMILAR HELD BACK TO INNER LEAF WITH WALL TIE CLIPS. WALL TIES TO BE STAINLESS STEEL AT 750mm HORIZONTAL c/cs AND 450mm VERTICAL c/cs. NOTE ROWS ARE TO BE STAGGERED AND WALL TIES TO BE AT 225mm VERTICAL c/cs AT JAMBS / INTERNAL LEAF 12.5mm PLASTERBOARD SCRIMMED AND SKIMMED ON DABS OF ADHESIVE ON 100mm DENSE CONCRETE BLOCKWORK (0.21 U VALUE) OPENINGS ALL EXTERNAL OPENING DIMENSIONS ARE EXTERNAL LEAF STRUCTURAL SIZES AND INTERNAL LEAF STRUCTURAL SIZES ARE 40mm LARGER TO FORM 20mm CHECK REBATE. PROVIDE VERTICAL INSULATED DPC TO JAMBS LAPPED WITH HEAD AND CILL DPCS GROUND FLOOR 100mm CONCRETE FLOOR SLAB ON 500g VISQUEEN ON 75mm THICK ECOTHERM INSULATION (NOTE 25mm INSULATION TO BE TURNED UP FACE OF WALLS AT EXPOSED WALL PERIMETER) ON 1200g VISQUEEN DPM LAPPED UNDER WALL DPC ON 50mm SAND BLINDING ON MIN 150mm WELL COMPACTED HARDCORE. (0.25 U VALUE) ROOF PREFABRIACTED INSULATED LIGHTWEIGHT CONSERVATORY ROOFING SYSTEM WITH TILE EFFECT FINISH TO MATCH MAIN ROOF FIXED IN ACCORDANCE WITH MANUFACTURES INSTRUCTIONS (U-VALUE 0.18) HEATING PROPOSED RADIATORS TO BE CONTROLLED WITH THERMOSTATIC VALVES GLAZING GLAZING LOCATED LESS THAN 800mm ABOVE FINISHED FLOOR LEVEL IN WINDOWS, 1500mm ABOVE FINISHED FLOOR LEVEL IN DOORS AND WITHIN 300mm TO SIDE OF DOOR TO BE SAFETY GLAZING TO BS 6206 PROPOSED SUN LOUNGE TO BE PROVIDED WITH BACKGROUND VENTILATION EQUIVALENT TO 8000mm2, EXISTING WINDOW TO LOUNGE TO BE PROVIDED ELECTRICAL PROPOSED INTERNAL LIGHT FITTINGS TO HABITABLE ROOMS TO BE FITTED WITH LOW ENERGY LAMPS. MAX 45 LAMP LUMENS PER CIRCUIT WATT ALL ELECTRICAL WORK TO BE CARRIED OUT IN ACCORDANCE OF A COMPETENT ELECTRICIAN IN ACCORDANCE WITH APPROVED DOCUMENT P DOORS / WINDOWS / ROOFLIGHTS SUN LOUNGE TO BE PVCU AND DOUBLE GLAZED WITH 0.05 LOW EMISTITY COATING AND 12mm GAP BETWEEN GLASS TO ACHIEVE MAX 1.5 U-VALUE FOR WINDOWS AND 1.5 U-VALUE FOR DOORS PROPOSED EXTERNAL LIGHTS TO ALL EXTERNAL DOORS TO BE PROVIDED WITH PIR AND DAYLIGHT CONTROLS BELOW GROUND DRAINAGE WHERE DRAINAGE PASSES THROUGH WALL PROVIDE PRESTRESSED CONCRETE LINTELS OVER AND OPENING SEALED WITH MASTERBOARD TO PREVENT VERMIN ENTRY FOUNDATIONS TO STEP UNDER DRAINS, STEPS TO BE MAX 225mm AND OVERLAP MINIMUM 450mm FURFIX OR SIMILAR CAVITY WALL STARTERS, EXISTING BLOCKWORK TO BE CUT TO LINK EXISTING AND PROPOSED CAVITY EXISTING BOUNDARY S/C RENDER WITH PAINTED FINISH TO MATCH EXISTING CODE 5 LEAD STEPPED LEAD FLASHING AND STEPPED CAVITY TRAY OVER PROVIDE WEEP HOLES TO EACH TRAY 100mm GUTTER TO MATCH EXISTING AND CONNECTED TO EXISTING RAINWATER PIPE EXISTING BOUNDARY PREFABRIACTED INSULATED LIGHTWEIGHT CONSERVATORY ROOFING WITH TILE EFFECT TO MATCH EXISTING PVC SUN LOUNGE WITH DOUBLE GLAZED UNITS TO MANUFACTUERS DESIGN S/C RENDER WITH PAINTED FINISH TO MATCH EXISTING CODE 5 LEAD STEPPED LEAD FLASHING AND STEPPED CAVITY TRAY OVER PROVIDE WEEP HOLES TO EACH TRAY EXISTING BOUNDARY EXISTING PATIO DOORS WHERE DRAINS PASS UNDER FLOOR PROVIDE 1200mm WIDE A142 MESH REINFORCEMENT TO SLAB EXISTING COVER REPLACED WITH DOUBLE SEAL INSPECTION CHAMBER COVER AND FRAME
Copyright in submitted documents remains with their authors. Request removal