==== PAGE 1 ====
Athol Park Guest House: Rear Part of House
SIZE
FSCM NO
DWG NO
REV
A1
APGH_ExtractApplication
A
SCALE
1:50
SHEET
12 OF 1
REV.
DESCRIPTION
DATE
BY
ADC
A
Initial Drawing
27/01/21
Notes:
1.
The existing extract arrangement was installed by the previous owners.
2.
The proposed extract arrangement is fitted with twin silencers and a “high velocity cowl”, which
spins the exhaust gasses up 15m to 30m.
3.
The proposed installation is designed to give a noise of less than 30dB A.
4.
The Cowl needs to start just above gutter height (8.8m to the Top of Cowl from Ground Level)
Athol Park Guest House: Existing Kitchen Extract Arrangements
0m
1m
2m
3m
4m
5m
Athol Park Guest House: Proposed Kitchen Extract Arrangements
Rear Roof
Rear
Kitchen
Door
Sitting Room
/ Store Room
Window
Window
Sitting Room
/ Store Room
Window
Toilet
Kitchen
Window
Room 4
Window
Room 10
Window
Room 9
Window
Room 9
Window
Bathroom
Window
Room 4
Window
Unused
Door
Room 5
Window
Roof
Boiler
House
Toilet
Main Roof
(front of Guest House)
Roof
Dining Room
Rear Window
Room 1
Window
Room 6
Window
Room 5
Window
Laundry
Room
Rear Roof
Rear
Kitchen
Door
Sitting Room
/ Store Room
Window
Window
Sitting Room
/ Store Room
Window
Toilet
Room 4
Window
Room 10
Window
Room 9
Window
Room 9
Window
Bathroom
Window
Room 4
Window
Fan
Silencer
Silencer
High
Velocity
Cowl
Kitchen
Window
Unused
Door
Room 5
Window
Roof
Boiler
House
Toilet
Main Roof
(front of Guest House)
Roof
Dining Room
Rear Window
Room 1
Window
Room 6
Window
Room 5
Window
Laundry
Room
Fan
Silencer
Silencer
High
Velocity
Cowl