REAR
GARDEN
STORE
CRAWL SPACE
REMOVE EXISTING DRAINAGE SYSTEM
AND REINSTATE WITH NEW ROUTES,
SOIL/FOUL DRAINAGE PIPES, RAINWATER
DRAINAGE PIPES AND INSPECTION
CHAMBER. CONNECT INTO EXISTING
COMBINED SEWER SYSTEM IN
ACCORDANCE WITH BUILDING CONTROL
ADVICE.
GARDEN TO BE CONCRETED / TARMAC /
PAVED TO CLIENT SPECIFICATION.
D3
D5
1.
2.
3.
4.
NEW INSPECTION
CHAMBER,
RW GULLEY
& SOIL PIPES
BLOCK UP DOORWAY
FININSH RENDER TO
MATCH EXSTING
BLOCK UP OPENING.
BUILD IN NEW DRAINAGE
PIPE. FINISH RENDER
TO MATCH EXISTING
NEW TIMBER EXTERNAL
DOOR TO ACCESS
CRAWL SPACE
BLOCK UP DOORWAY
FININSH RENDER TO
MATCH EXSTING
COMBINED
SEWER
INCOMING
WATER MAIN
NEW TIMBER
EXTERNAL DOOR
TO ACCESS STORE.
REDUCED HEIGHT
OF LINTEL & MAKE
GOOD RENDER
DEMOLISH INTERNAL WALL
LOWER FLOOR JOIST
IP RATED
OUTDOOR SOCKET
PARTLY DEMOLISH REAR STONE WALL TO WIDEN
REAR ENTRANCE OF GARDEN. INCREASE OPENING
TO 4200mm THIS ALLOWING FOR INSTALLATION OF
A NEW, DOUBLE TIMBER GATE. CONSTRUCT A
MASONRY PIER AND TIE-IN TO EXISTING MASONRY,
ENSURING STABILITY TO THE REMAINDER OF THE
REAR WALL. REINSTATE MASONRY/ RENDER/
HAUNCHING, AS REQUIRED AND AS PER EXISTING.
LANDING
1F ANNEX
LANDING
1F
STUDY
BEDROOM 3
LANDING
2F
ENSUITE 1
UTILITY
BEDROOM 1
SNUG
WC
M&E
CUPBOARD
ENTRANCE
HALLWAY
ENTRANCE
PORCH
+/-0mm FFL
-1542mm REAR STORE
+2807mm ANNEX 1F
+7554mm ANNEX RIDGE
+3306mm 1F
+6393mm 2F
+10750mm RIDGE
STORE
UNDERCROFT
CRAWL SPACE
3X2 TIMBER STUDWALLING
ACOUSTIC INSULATION BETWEEN
STUDS. DOUBLE BOARDED WITH
ACOUSTIC PLASTERBOARD12.5mm
STAGGERED JOINTS AND SKIM FINISH
4X2 TIMBER STUDWALLING
ACOUSTIC INSULATION BETWEEN
STUDS TO UTILITY WALLS ONLY.
12.5MM PLASTERBOARD & SKIM FINISH
BRACE CEILING WITH 5X1 TIMBER
REFORM STAIRCASE
TO ORIGINAL LAYOUT
AND ADJUST
POSITIONING INTO
ANNEX
RIGID INSULATION BETWEEN ROOF JOIST
AS PER BUILDING CONTROL REQUIREMENTS
BLOCKUP OPENING TO STORE ROOM.
REDUCE HEIGHT OF EXISTING WC OPENING
BY INSTALLING PRESTRESSED CONCRETE LINTELS
BUILDING IN WITH MASONRY ABOVE.
SET LEVEL FOR FLOOR JOISTS AND LOWER EXISTING
INTO POSITION, ENABLING A LEVEL FLOOR ABOVE IN THE
SNUG. POCKETS TO BE MADE IN EXISTING MASONRY TO
THE FAR SIDE AND FLOOR JOIST ENDS TO BE WRAPPED
IN DPC BEFORE BEING BUILT BACK IN WITH MASONRY.
NEW FLOORING TO MATCH EXISTING AS REQUIRED.
12.5MM PLASTERBOARD FITTED TO STORE CEILING.
NEW 12.5mm PLASTERBOARD CEILING
SKIM FINISH
NEW 12.5mm PLASTERBOARD
CEILING SKIM FINISH
NEW 12.5mm PLASTERBOARD
CEILING SKIM FINISH
NEW 12.5mm PLASTERBOARD
CEILING SKIM FINISH
3X2 TIMBER STUDWALLING
PLASTERBOARD12.5mm
STAGGERED JOINTS AND SKIM FINISH
WOOL INSULATION BETWEEN ROOF JOIST
AS PER BUILDING CONTROL REQUIREMENTS
D1
W9
SNUG
KITCHEN
LOUNGE / DINER
OPEN PLAN
ENTRANCE
HALL
WC
REAR
ENTRANCE
HALL
FRONT
GARDEN
REMOVE ALL FIXTURES/FITTINGS,
WALLS COVERINGS &
PARTITIONS, CEILINGS AND
RAISED FLOORING AS REQUIRED.
MAKE GOOD PLASTERING
WORKS AS REQUIRED
M&E CUPBOARD
D1
D2
W1
W2
W3
W4
W5
W6
W7
W8
DW
OH
FF
HD
CO
BOILER
VENT
SD
CO
HD
SD
FAN
SD
A-A
A-A
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
6.
5.
4.
3.
BLOCK UP DOORWAY
FININSH RENDER TO
MATCH EXSTING
20 WATT LED
FLOODLIGHT AND
MOTION SENSOR
6 WAY 3 PHASE
DISTRIBUTION
BOARD
30KW WORCESTER
GAS SYSTEM
UTILTY BOILER
300LTR
UNVENTED
HOT WATER
CYLINDER
NEW STUDWALLS &
DOORS TO FORM NEW
PLANT ROOM AND WC
BOILER VENT,
HIGH LEVEL BOX-IN
WITH ACCESS PANELS
BLOCK UP
FIREPLACE
(VENT)
BLOCK UP
FIREPLACE
(VENT)
INCOMING
ELECTRICAL
FEED. INSTALL
3PHASE ISOLATER
INCOMING GAS FEED
MAKE CONNECTION &
ROUTE TO M&E CUPBOARD
PARTIALLY DEMOLISH DIVIDING WALL
TO PROVIDE OPEN PLAN LIVING.
SEE STRUCTURAL ENGINEERS ADVICE FOR
STRUCTURAL DETAILS.
BOX-IN STEEL AS REQUIRED
AND BUILD NEW STUD PIER TO RIGHT.
SPECIALIST TO ADVISE ON
SUITABILTY OF EXISTING LOG
BURNER /FIREPLACE/CHIMNEY
REINSTATE HALLWAY WALLS
NEW STUDWORK AND DOORS
REFURBISH PORCH ENTRANCE,
RETAIN ORIGINAL FEATURES
THROUGHOUT HALLWAYS.
INSTALL NEW DOOR
KITCHEN
EXTRACT
W5 - RAISE INTERNAL CILL
HEIGHT TO 1200mm ABOVE FFL
W6 - RAISE INTERNAL CILL
HEIGHT TO 1200mm ABOVE FFL
LANDING
1F ANNEX
BEDROOM 1
LANDING
1F
TD
ENSUITE 1
UTILITY
WM
REMOVE ALL
FIXTURES/FITTINGS, WALLS
COVERINGS & PARTITIONS,
CEILINGS AND RAISED
FLOORING AS REQUIRED.
MAKE GOOD PLASTERING
WORKS AS REQUIRED
ENSUITE 2
WARDROBE
BEDROOM 2
MASTER SUITE
STUDY
W9
W10
W11
W12
W13
SD
SD
FAN
FAN
HD
14.
15.
16.
17.
18.
11.
12.
13.
1.
20.
21.
22.
2.
19.
REPLACE LOFT HATCH
NEW STUDWALLS AND DOORWAYS
TO FORMNEW LAYOUT -
BED1 / ENSUITE1 / UTLITY
EXPOSE AND REINSTATE
FIXED ROOFLIGHT &
LIGHT TUNNEL
RECONFIGURE LANDING
TO ORIGINAL REPOSITION
STEP INTO ANNEX
NEW STUDWALLS AND DOORS
TO FORM NEW ROOMS -
ENSUITE2 / WARDROBE
BLOCK UP
FIREPLACE
(VENT)
BLOCK UP
FIREPLACE
(VENT)
BATHROOM
EXTRACT
NEW STUDWALL
TO FORM NEW ROOM -
STUDY/GUEST BEDROOM
FORM NEW
DOORWAY
BEDROOM 3
BEDROOM 4
LANDING
2F
FAMILY
BATHROOM
W14
W15
W16
SD
FAN
28.
27.
26.
25.
24.
29.
30.
31.
32.
33.
34.
23.
BLOCK UP
FIREPLACE
(VENT)
BLOCK UP
FIREPLACE
(VENT)
REPLACE LOFT HATCH
FRAME OUT FOR NEW ROOFLIGHT
SIZE TBC WITH SITE MEASURE.
ASSUMED 450X450mm
DEMOLISH CHIMNEY AND MAKE GOOD
TO CONSTRUCT PARTY WALL BETWEEN
LOFT SPACE OF NEIGHBORING PROPERTY.
CHECK ROOF TIMBERS
AND REPLACE AS REQUIRED
NEW ROOFLIGHT
REPOSITIONED
TO MATCH RL1
REPLACE LOFT HATCH
STRIP ROOF TO FIX NEW BREATHER MEMBRANE
AND RELAY. NEW DRY VERGE AND LEADWORK,
REUSE SLATES AND RIDGE WHERE POSSIBLE.
REPOSITION AND REPLACE ROOFLIGHT IN BED 3
TO MATCH EXISTING IN BED 4.
INSULATE AS PER BUILDING REG. REQUIREMENTS.
CHECK CHIMNEYS FOR REPAIR.REAR ROOF OF
MAIN BUILDING REQUIRES PARTIAL STRIP ONLY AS
BREATHER MEMBRANE ALREADY IN PLACE.
RL3
RL2
RL1
RL4
NEW ROOFLIGHT
REPOSITIONED
TO MATCH RL1
BATHROOM EXTRACT
SLATE VENT
BATHROOM EXTRACT
SLATE VENT
SOIL STACK
VENT
CAP OFF UNUSED CHIMNEYS
WITH CLAY FLUE VENTILATORS
NEW FOUL
/SOIL/RAINWATER
DRAINAGE
W4
W5
D2
D5
W12
W13
W7
W8
W14
W15
RL4
REPAIR EXTERNAL RENDER ON ALL
ELEVATIONS AND GARDEN WALLS
WHERE CRACKS ARE VISIBLE. WHERE
LINTELS & CILLS ARE TO BE REPLACED
ENSURE PRECAST CILLS & RENDER
ARE REINSTATED TO MATCH EXISTING.
FURTHER ASSESSMENT REQUIRED TO
CONFIRM EXTENT OF RENDER WORKS.
REPLACE ALL WINDOWS
AND ENTRANCE DOOR AS
PER WINDOW SCHEDULE
BATHROOM
EXTRACT VENT
KITCHEN
EXTRACT VENT
20 WATT LED
FLOODLIGHT AND
MOTION SENSOR
MAKE REPAIRS TO
SMALL ROOF AND
VERGE HAUNCHING
GREY/WHITE/BLACK
MASONRY PAINT TO
ALL EXTERNAL WALLS
NEW DRY VERGE
BLACK/GREY
REPLACE ALL RAINWATER
DRAINAGE TO MATCH
EXISTING - BLACK
BLOCK UP OPENING TO
STORE. RENDER SMOOTH
TO MATCH EXISTING
IP RATED
OUTDOOR SOCKET
NEW TIMBER EXTERNAL
DOOR TO ACCESS
CRAWL SPACE
20 WATT LED
FLOODLIGHT AND
MOTION SENSOR
GAS BOILER
VENT
BLOCK UP OPENING
BUILD IN NEW DRAINAGE PIPE
CAP OFF UNUSED CHIMNEYS
WITH CLAY FLUE VENTILATORS
NEW FIXED ROOFLIGHT.
ORIGINAL FEATURE
REINSTATED.
DEMOLISH UNUSED CHIMNEY
TO BELOW RIDGE LINE. REINSTATE
ROOF TO MATCH EXISTING.
BATHROOM EXTRACT
SLATE VENT
NEW DRY VERGE
BLACK/GREY
STRIP ROOF TO FIT BREATHER
MEMBRANE & INSULATION.
REUSE RIDGES & SLATE. MATCH
TO EXISTING WHERE REQUIRED
SIDE WALL
HEIGHT
W5 - RAISE INTERNAL CILL
HEIGHT TO 1200mm ABOVE FFL
D1
W2
W3
W9
W10
RL2
RL1
REPLACE ALL WINDOWS
AND ENTRANCE DOOR
AS PER WINDOW
SCHEDULE
REPLACE ALL RAINWATER
DRAINAGE TO MATCH
EXISTING - BLACK
MAKE REPAIRS TO SMALL
ROOF AND VERGE
HAUNCHING
GREY/WHITE/BLACK
MASONRY PAINT TO
ALL EXTERNAL WALLS
REPAIR/PAINT METAL
RAILING & GATE - BLACK
NEW ROOFLIGHT
REPOSITIONED
TO MATCH RL1
STRIP ROOF TO FIT BREATHER
MEMBRANE & INSULATION.
REUSE RIDGES & SLATE. MATCH
TO EXISTING WHERE REQUIRED
NEW LEAD
FLASHINGS
NEW DRY VERGE
BLACK/GREY
NEW DOOR BELL
EXTERNAL
ENTRANCE LIGHT
FENCE HEIGHT
CAP CHIMNEY
CLAY VENTIATOR
W6
W11
W16
RL3
REPAIR EXTERNAL SMOOTH RENDER
ON ALL ELEVATIONS AND GARDEN
WALLS WHERE CRACKS ARE VISIBLE.
WHERE LINTELS & CILLS ARE TO BE
REPLACED ENSURE RENDER
REINSTATED TO A SMOOTH FINISH TO
MATCH EXISTING. FURTHER
ASSESSMENT REQUIRED TO CONFIRM
EXTENET OF WORKS.
REPLACE ALL
WINDOWS AND DOORS
AS PER WINDOW
SCHEDULE
NEW LEAD
FLASHINGS
NEW DRY VERGE
BLACK/GREY
BATHROOM EXTRACT
SLATE VENT
NO FULL ROOF STRIP REQUIRED.
ROOFING FELT PREVIOUSLY FITTED.
(INSULATE FROM BELOW)
GAS BOILER
VENT
CAP CHIMNEY
CLAY VENTIATOR
NEW LEAD
FLASHINGS
20 WATT LED
FLOODLIGHT AND
MOTION SENSOR
NEW DRY VERGE
BLACK/GREY
NEW FOUL /SOIL/
RAINWATER DRAINAGE
- GREY/BLACK
PARTLY DEMOLISH REAR STONE WALL TO WIDEN REAR ENTRANCE OF GARDEN.
INCREASE OPENING TO 4200mm THIS ALLOWING FOR INSTALLATION OF A NEW, DOUBLE
TIMBER GATE AND EASIER ACCESS. CONSTRUCT A MASONRY PIER AND TIE-IN TO
EXISTING MASONRY, ENSURING STABILITY TO THE REMAINDER OF THE REAR WALL.
REINSTATE MASONRY/RENDER/HAUNCHING AS REQUIRED AND AS PER EXISTING.
W6 - RAISE INTERNAL CILL
HEIGHT TO 1200mm ABOVE FFL
KITCHEN
EXTRACT VENT
D3
D1
D2
D4
T
S
T
S
T
S
T
S
T
S
T
S
T
S
T
S
T
S
T
S
panel
W1
W2
W3
W4
W5
W6
W7
W8
W9
W10
W11
W12
W13
W14
W15
W16
T
S
T
S
T
S
T
S
S
S
S
T
T
T
T
T
T
T
T
T
T
T
S
S
T
RL2
Drawing:
PROPOSED Floor Plans / Elevations / Sections /
Windows Schedule
Date:
March 2021
Scale:
1:100 unless otherwise noted
Drawing Number:
2101-P-02A
Revision:
A
Drawn by:
Barry Lees
64 Hailwood Avenue
07624267268
GROUND FLOOR PLAN
FIRST FLOOR PLAN
SECOND FLOOR PLAN
ROOF PLAN VIEW
SIDE ELEVATION
FRONT ELEVATION
REAR ELEVATION
REAR GARDEN PLAN
SECTION A-A
PROPOSED WINDOW & DOOR SCHEDULE
NOTES FOR WINDOWS AND DOORS:
PAS24 / SECURE BY DESIGN. OR
EQUIVALENT.
Windows:
PVC Casement windows.
Stub Cills (where required).
Hinged as indicated.
Transoms - central split if possible, or as
close as, pending manufacturers size
restrictions.
All double glazing.
Toughened as indicated (T).
Stippolite as indicated (S).
Colour - Anthracite Grey out - White in
RL2 - Velux rooflight to match RL1
Doors:
D1- PVC style as per image**
D2 - PVC Standard panel
Standard Threshold
Hinged as indicated
open in
All double glazing.
Toughened as indicated (T).
Stippolite as indicated (S).
Colour - Anthracite Grey out - White in
D1 - if size not suitable for 2x sidelight
then change formation to 1x sidelight on
left hand side (viewed externally)
D3 & D4 - TIMBER EXTERNAL BESPOKE
SIZES
Project:
Refurbishment works -
8 Brunswick Road Douglas Isle of Man
IM2-3NS
PLANNING ISSUE
PROPOSED CONSTRUCTION NOTES:
MAIN ROOF: Strip front of main roof to
install new breather membrane. follow
building control guidelines & Regulations for
re-roof. New breather membrane, felt
support trays, treated timber roofing battens,
lead flashing to chimney stacks and plastic
dry verges as required. Rooflight RL2 to be
replaced and repositioned to match RL1.
fitted as per manufacturers instructions.
Cap-off unused chimneys with clay
ventilators to suit existing. Chimney
specialist to advise on suitability and any
remedial works to lounge log burner and
chimney. Rear side of main roof has felt
previously fitted, partial strip only required to
fit new verges, replace leadwork if required
and installing slate roof vent for bathroom
extraction. Ensure all works in accordance
with ... reaching a U-Value of ...
REAR ANNEX ROOF:
Roof strip and replace as per main roof
description. New fixed rooflight to fit into
existing light tunnel to the 1F annex hallway.
Chimney to be demolished to below ridge
line ensuring the roof is made good with
replacement ridge and slate as per existing.
Roofing works to 8 Brunswick Road only.
EXTERNAL WALLS:
Contractor to further assess external
masonry walls to advise extent of works.
Cracks to be grinded out and flexible mesh
fitted to stonework with joints being filled
and render repaired to a smooth flush finish.
Ensure sand/cement/lime mortar mix. All
patches of new render to be blended and
matched to existing. Openings in masonry
to be blocked up using dense concrete
blocks/bricks with sand/cement mortar, use
masonry ties as necessary, finish plaster to
match existing.
LINTELS AND CILLS:
Contractor to further assess lintels and cills
to advise extent of works. repair as required
with replacement cills to be precast concrete
to match existing. Any lintel replacement to
be 150x100mm prestressed concrete. DPC
and weep holes as necessary. Make good
render to be blended and matched to
existing.
FIREPLACES:
Block up fireplace using dense concrete
blocks / bricks. ensure air brick built-in to
enable ventilation via hit and miss vents
fixed after plastering.
WINDOWS AND DOORS:
All windows and door to be replaced as per
window schedule. Ensure secure by design
or equivalent. PVC, Grey on white. Windows
to be provided with suitable hit & miss
ventilators to provide 8000mm square
background ventilation to habitable rooms
and 4000mm square to Kitchens, Utility
Rooms and Bathrooms, to comply with Part
F1 section 1 of Building Regulations.
Factory sealed double glazed units to all
windows to be made up as
follows:-Pilkington 4mm Optifloat/12mm
air/Pilkington 4mm K-Glass. With a
minimum Window Energy Rating (WER) C,
or overall U Value of 1.6W/m2K Door
Glazing to minimum U Value of 1.8W/m2K.
Door to receive double glazed units as
windows but with internal safety glazing to
comply with BS 6206 and Part N. Building
Regulations 2014. All new doors and
windows must also been approved by
Secure by Design or have a certificate
issued to this effect by an approved body.All
areas of glazing between finished floor level
& 800mm and any door glazing between
finished floor level and 1500mm above floor
level and any side panels within 300mm of
door should be fitted with safety glazing to
comply with Part N1 ( 1.1 ) Building
Regulations.
GARDEN FRONT:
Make repairs as necessary and paint
external walls and metal railings/gate.
GARDEN REAR:
Excavate for new drainage. Block up side
entrance in masonry & Make repairs as
necessary, All new patches of new render to
be blended and matched to existing
and external walls painted using masonry
paint. Replace Timber gate to rear entrance,
like for like. Upon backfill of drainage lay
100mm of compacted hardcore to allow for
new covering as per clients specification.
RAINWATER DRAINAGE:
New rainwater drainage goods to match
existing PVC. Reposition downpipe leading
to new gulley on rear annex elevation. new
gulley to link with new inspection chamber. .
FOUL DRAINAGE:
New foul and soil pipes to as per layout,
venting above gutter line on rear elevations.
soil stacks to link in with new inspection
chamber.
UNDERGROUND DRAINAGE:
New inspection chamber to carry
rainwater/foul/soil waste and link into
existing. Collapsed chamber to be exposed
and investigated with building control before
connections made. All drainage works
carried out with building control officers
approval.
INTERNAL WALLS & CEILINGS:
New studwalls to be constructed to match in
with existing construction. Generally 3x2
treated timber with 12.5mm plasterboard
either side, skim finished using 2nr. coats of
multifinish plaster. unless otherwise noted..
New/replacement ceilings to be boarded
using 12.5mm plasterboard and skim
finished. Existing ceilings with extensive
cracking to be overloaded where required
using 9mm plasterboard and fixed with
screws at recommended spacing. Strip all
wall coverings to assess extent of works,
Any walls/ceilings in good condition to
receive coating of plasprime bonding agent
and over-skimmed using multifinish thistle.
Carry out repairs to any masonry walls
before over-skimming with
sand/cement/lime mortar to a scratch float
finish. Carry out repairs to internal walls
using thistle bonding and/or timber noggins
with 12.5mm plasterboard before overskim.
Bathroom walls to be fitted with "Multipanel
boards" & tiled as per clients specification.
pipe boxing to be constructed using 2x2
timber and finish in ply or plasterboard
appropriately dependant on finishes.
INTERNAL FLOORS & GENERAL
JOINERY:
Replace flooring as required with floorboard
to match existing 22mm. For larger areas
22mm chipboard flooring, moisture resistant
flooring in wet areas. Replace all internal
doors, skirting's, architraves and cill boards.
BATHROOMS:
Bathroom fit out as per clients specification.
Drainage to fall to the rear of the property
into new soil stacks. Vent Axia or similar
extractor fans, ducted to outside-air, wired
to approved humidistat. Extract rate to be
minimum 30 Litres/second to comply with
Part F1 Section 1.5 of Building Regulations
- Electric towel rails & underfloor
heating mats specified additionally.
KITCHENS:
Kitchen design as per client specification.
Extract rate to be minimum 60 Litres/second
to comply with Part F1 Section 1.5 of
Building Regulations 2014.
ELECTRICAL:
All electrical works to be carried out by a
competent person. test and certificate in
accordance with BS7671 & Part P electrical
safety. Full rewire to clients specification.
New 6-way 3-phase distribution board, with
3phase isolator.
PLUMBING:
All plumbing works to be carried out by a
competent person test and certificate in
accordance with... new plumbing system
and fittings to clients specification. 30kw
Worcester gas system utility boiler, 300l
cylinder. 1x WC, 2x Ensuite, 1x Family
bathroom as per drawing layout.
DEMOLITIONS:
All demolitions to be safely carried out by
contractors and method statements
produced. waste should be disposed of
responsibly making use of local construction
waste recycling plants.
GENERAL:
Contractor to seek advice from utility
providers and confirm relevant works before
commencement (MUA, water, electricity,
Drainage, Manx Telecom).Contractor to
liaise with Building Control officers and
ensure all materials used and any works
carried out, satisfy building control
requirements.Contractors to be
appropriately qualified and competent,
ensuring all relevant codes of practice,
approved documents an Building
Regulations are adhered to.
DRAWING REVISION NOTES: rev-a
Annotations
Garden gate opening increased
W5&W6 cill heights raised
8 Brunswick Road Douglas Isle of Man IM2-3NS sits within a Conservation
Area. "The Douglas (Selbourne Drive) Conservation Area"*.
The Conservation Area shaded grey on the location plan. Considerations
should be made on style of windows and doors and confirmed with the
planning department before order. Many properties on Brunswick Road
have had windows and doors replaced, generally window replacements
are a standard white PVC Casement, double glazed with a central transom
split. Door styles vary between reconditioned original timber and new PVC
styles.
This drawing shall not be scaled. all dimensions
to be confirmed on site. All levels and
dimensions are to be checked on site by the
Contractor prior to fabrication, and any
discrepancies must be reported immediately to
the Designer.All dimensions are to be read off
this drawing and NOT scaled. All work to be
executed in strict accordance with the Building
Regulations of the local authority. All work to
conform to applicable Codes of Practice and
industry standards.
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION