Loading document...
==== PAGE 1 ====
UPv'c.G89'ementwind eo (GcIO\Jr:~Ite) Gcneerv8tion roofllghts I Rev. Drawing No. 1405/09 r '1~ l:'OO/':~ SAMSON DESIGNS LTD The Wotkshop. P;j,k Il.o<>d.Pot! St.M,ty. IslearM," lM9 SHQ Tel: (01624) 837545 Email: [email protected] st. Hary's House, High street, Port st. Hary Project .' ",~C~:WEO0111 ~ecei~;-'2 7 024,lA?R2~,fl ('J 0 4 5 3 DEPARTMENT OF INFRASTRUCTURE PLANNING andi~UILOI C;~01\IO-RI)L ItvlJi>iifi'ik;'u Town aO(i r;fj'.' ,1,- r j!j9 UpVG traditional 'tilt' sash window (ColOur: ~ite) Rendered l painted walls Fibre/cement roofing 'elatee'. The roof generally re'lulree upgrading with new 'slatee'. battene, roofing felt tlnd Improved lnsultltlon. Date Scale Drawing Existing Sec.ond Floor Plans 4 Elevations front (Ea5t) Elevation "lOa Flat roof dormer over the etudy 300. Gcnservstron roofllghte to front (Ea&t) elevatron 5ee Reelr (Y"Ieet)Elevation Purl.!.!:l.- _ study .. 1'/.1 pur.!l!:l-k _ Rendered l pelinted walls E)(ieting dormer£>with GoRP flat roof UpVG traditional tilt' eash window (Gclour: ~Ite) UpVGrainwater goode (Colour: Blac.k.) UpVGfully glazed patio doors (Gclour; Jl"ihlte) .' Landing o '.
pi
Sec.ond Floor Plan 1,50
ear (V'le5t)Elevation "lOa
Flat roof dor
e
er the bedroom
Exietlng U
bedroom to
==== PAGE 2 ====
Rev.
DrawirwJ No.
1405/04
r'15
llOV/l~
Drawong
Proposed Second Floor
Plans /I Elevations
Project
st
Mary's House.
High street.
Port st
Mary
ront
and rear
elcVI!IItiorn>to
be re-roof'ed
With
new
Marley
'Rivend8le'
'ibre/cement
'alat~.,
PROPOSED
SAMSON
DESIGNS LTD
rhe Wod<,hop.
Park Il.oa<l.Port Sl.Maty.
1,leo(Man
IM95HO
Td
(01624)
837545
EmJ.! ~mKlIl<lol~n""mJIl>lllct
r';~eived-- 2 704
15
15 '00-4' 53
I
DEPARTMENT2F \!')It:RAST~U.CT'JRE
'~U,i~NINGana,31J!LO!i\iG GONT,GL
"'DI\f!SI(~r\'
Townand Coun1}.APR,~m5 -'."°99
.
'1<'''.
i'
;<115
. .
- -
°I.'PARTMc"-\'O$.'
j
OE:c!~:or'i
/IvFR~STRU(>,\0~
1
f.
-;;'1-;;,:;-T-- -- --=-__
I 1
__
1
I
I
I
I,
Front (Ea9t) Elevation "'00
•
New .tud
pe,.tition
to be 15 x 50mm
!ow !>tude •
400mm
centree
with 12.5mm plllelered
boa,..d ~
!ok-1mboth !llde!>. i5mm
thlGk K!n,gSPMl KQotthenn
1(,1;2ri9id lnflulatlon, or approved alternatIve, to be
fitted
between
f>tud~
in
ac.GOrdanu
with
rt\llInufac.turer~ln6truction!!o.
.'
ew Velul( 'c.on~ervm:lon'rocfllght
over the
~t8iNleli.
--Exi&tif\<3
dormer. to be removed and repfac.ed
witH Velul( Gombinationroortfgl'lt&.
El.!IGhVelux GombiMtion unit
i~ :2520mm l(
cwomm with l00mm allO!J.'.llnGe
between eac.h
unit. The unite cone-jet of fixed
lOwer panela
and top
nu"g upper
panel~_ frames
to
be
Dark. Grey.
-Opaq,ue
glazed
panel to
the
elde o~ the
el<i&tingdoor
r
..
New "tud partition
to create.
!lmalle'" f1tore
room and provide IIITV alGOveIn the .tudy.
I
E)(letll"l9 ma61er bedroom
WindOW to
be
widened
Tl'le new wmdow to
be
a upVG
traditional
6tlJle tilt'
10M" window to lTIetG.h the
exieting upvl wlndO\.l}$ to
the
rear
elevtStlon,
Golour: r"ihlte.
New VeIUl( 'Coneervllt.lon' roc'll~ht ever
the
!ltsirwell. To match the exilotlr'\9
t.o the 'rOt'll
elevatIon.
El(iet!r19 dormer.
to be remo~ed and reptaGed
- with Velu)i( Gombinatloo rooflight.,
GCMl6ting
of
fixed
lower panel!> and top
hunta upper
panel6. Frome. to be DtlIrk Grell
lJ
'.
Store
..'.•-.
-- \ .
-
,
I . -
-
I
,
I
•
--I
°r-I
DL:T
uite
Landing
5tudy-- -
--
--
--::I
Eledroom
';\ll/lrA
1;\111"'
I
II
\ II /
[
! H~
LJL-.l
LI
... --l
I -
A~
Second Floor Plan 1.50
Rear (~ef>t) Elevation
1.100
I
==== PAGE 3 ====
5ee 5truc.turtll Notes
Newwindow to master bedroom
.,
•
Y'tINDOI"i5
New windows must be tiS a minimumof
" type with
ll'iindow Energy Rating (YER)C., or overall U-valueof
1.bY'tlm""K.
They mu!>telso have been approved btJ
5ec.ure by Design or have a Gertific.ate issued to
thi~ effec.t by an UKASapproved body.
Bullding Control will require, at the completion of
the work~, a c.ertiflc.ate issued by the contractor
to
confirm
that
they have in!ltalled the relevant
type of window. in' COmpllanc.ewith the above, 85
required under the Building Regulation~ :2014
The new window to
the
master
bedroom
to
be
supplied
and
lne.talled by Everest
to
matc.h the
existing windows to
the rear
elevtltlon.
To be a
upvc. double glazed traditional
'tilt'
!la~h ~indow
unit. complete with tric.kle ventilation and vertlc.al
OPe. to all Jamb5. The external render .to
form
a
25mm external rebate to
the window openirrg for
'severe weather exposure' (c.ategory 4) to prevent
the ingress of wind driven rain.
",'".
.
Trick.le
vent~
within
the
frames
to
provide
OOoomm""ventilation per habiblble room.
nindows
to have opening lights equivalent to 1I2oth of the
floor space to be ventilated,
If any part of the new window is less than 800mm
above floor level then it w1llrequire Mfety gl8S!5.
NOTE:The top hung velux rooflights
to the ~ec.ond
floor are to provide an unobetructed openable area
to
be at lea6t 0.33m2 and the minimumheight or
width of the opening must not be le!l! thl!lln450mm.
l .' .Jl:le...battam of the opc;nab1e "rct:! tp be a ~
g6el~W'1"1l"4"f~lloor.15
CJ0 4 S ~
DEPARTMENT OF INFRI\STRUCTURE
PLANNING and BUILOING CONTROL
ra,~\P;'L~,
.
G""... '-U 0
Pro
_,
_
.
~'V
_.::' ~:i;als I,
~t;i'IVI~r
's HO\,ls~J:U 0
1t.tigt1
treet .
-.-f?
/, "~;A~ IM~.~;
-:..J
t
,sTRUC' ,-,-
I
•
ROOF
Existing Roof pitch = "pprox 3d'
The exl!lting roofing tllee. and battens to the fj:ont
and rear elevation ere to be taken off. The exie.ting
two
dormers
to
the
rear
elevation
are
to
be
removed
for
replacement
with
new
Velux
Combination rooflights.
The timber
rafters
are
supported
on
existing
timber purlins and trusses. All are to be checked
for
rot
or
damttge
and
treated/repaired
as
necessary.
: New roofing tHes-are to be:Marley Rivendale fibre
cement slates.
To be mec.hanic.allyfixed
to
meet
Marley ~oflng
recommendations
4: B.5 5554 for
severe to very severe expOS'urecategory. Roofing
tiles
be nailed to
new 50
x :25mmt2lnalised aw
battens
over
a
layer
of
breethable
!!larking
membranee.g Kln.g!!lpan'Nilvent' with ttlped !leams.
•
ROOFLI6HT5
11"10.
Velux
ACoS CCnservation
roofllght
to
be
installed over the stairwell. Size, 460mm x b10mm.
The ineulatlon Is to
form a ventih!lted roof
using
15mm Kingspan !<OOlthermK; Pitched Roof
Board
fitted
between
the
existing
rafter~
(as~umed
existing rafter
depth of
1,25mmJ.The insulation to
partially fill the depth of the rafters
to leave e min.
50mm vent!teted air spac.e above, The rafters
ere
to be underlined with b2.~mm Klng!lpan !<OOltherm
K18 Insulated Dryllnln9 board,
comprising
1.2.5mm
pltlsterboard
and 50mm insulation. The Insulation to
be
tightly
fitted.
at
roof
perimeter
to
ensure
continuity between roof and wall Insu!etlon.
Ventilation
of
the air gtlp i!!l to
be provided
at
eaves
level
equivalent to
Gontinuous ventilation
runninq the full length of the eeves and :25mmwide,
Ventilation
fit
the
ridge
to
be
equivalent
to
continlJOlJsventilation running the full length of the
ridge and 5mmwide to be provided by proprietary
ventilators below the ridge tiles.
cede 4 lead flashings, soakers and cover fla~hing
to be used through out to valleys and abutments
unle~s otherwise stated.
Rairweter to dlec.harge from roof Into the exl~tlng
100mm di". hellf round upvc gutter!> with matching
"T5mm dla. rwp.
Bedroom
TOp hungVelux rooflight
Line of the original dormers shoLlmdotted
er Velux rooflight
fixed I
Ensuite
on Co:20
GOncrete
c.upboard
"
The lintel ends to
be bedded
padstonee.(min.:215mmdeep)
•
5TRUGTURAL
The
exletin9
window
opening
to
the
Master
bedroom
to be widened with new 140 x 100mm Pre-
stree.sed conc.rete
IIntel~ over
the
opening. The
number of
lintel!> to
suit
the
thlckne!ls
of
the
existing solid masonry wall. (Colear span " 1eoO~m),
The external render and internsl plaster to be made
good,
Drawing
Sec.tionAA
(Buildin9 Re9u1ation Notes)
SAMSON
DESiGNS LTD
The Workshop.
Pa,k Road, Port St.Mary.
151~o( Man
IM9 SHQ
TeL (01624)
837545
Email: S<lmson••esI9n~manl4.net
Rev.
Drawing
No.
.1405/05
Date
r'15
Scale
1:50
All Velux roofllghts to be fitted
in 2lGGOrdancewith
the manufac.turer'$ rec.ommendationecomplete with
tlll flsshing!l etc.; tlnd double rafter
trimming to all
side$ of the opening.
Velux CCmblnatlon roofllght~
to be Installed in the
position
of
the
original
dormer~.
Each unit
to
consist of a fixed lower base panel for protection
against
ftllfl"9.
with a top
hung upper
pzsnel as
Indicated
on
the
plen!>
4
elevations.
3nO.
combination units to be provided
in the Bedroom
and :200. comblMtlon
unlt!l to be provided
in the
Study_ OVerell each unit to be :2~20mm x CWOmm
Gonsl!ltlng of,-
•
upper panel: Top hungVelu)( GPL P10. Size ~
x 1600mm
•
68!1e psnel: Fixed Ve!ux
<SoIL P34, Size C\4O X
q;,zOmm
All
to
fitted
within
the
appropriete
Velux
combination
frtlme!l,
with
e
100mm
ellowanc.e
between the Indlvldutll comblMtlon units. COlour of
frames to be Derk Grey.
Sec.tion AA 1,SO
•
Electrlce., All electrical work to be carried out by a'
GOntr2lGtor or
pereon
regi!ltered
under
the
'competent Persons 5Gheme'.If the work is to be
carried
out by a person other
than a regl!>tered
competent perf>on, e.g. a self-build project,
then a
full di89rammatiGla~out and detail!> of the eJectriGal
Installation should
be provided
for
approval
by
Building COntro1. Financial penaltie!l and f1dditlonal
charges can be Imposed by Building centrol
if thie.
requirement Is not compiled
with.
Copyright in submitted documents remains with their authors. Request removal