==== PAGE 1 ====
Client
Hospice Isle of Man
Drawing Information
Purpose of Issue
New Mezzanine storage area
Unit 13-14, Springham Industrial Estate,
Douglas, IM2 2QS
Drawing Title
Contract
Proposal Drawing
PLANNING
03
Drawn by
Drawing number
Rev
Scales @ A1
Date
23 West Quay
Ramsey
Isle of Man
IM8 1DL
Tel: 01624 813219 / 814178
Fax: 01624 816436
[email protected]
www.penkethmillar.co.uk
General notes
- This document and its design content is the copyright
© property of Penketh Millar Ltd. and may not be
reproduced in any way without the permission of
Penketh Millar Ltd. It shall be read in conjunction with all
other associated project information including models,
specifications, schedules and related consultants
documents.
- Do not scale from documents, written dimensions to
take preference at all times.
- All dimensions & levels to be checked on site prior to
construction or fabrication of any elements. Immediately
report any discrepancies, errors or omissions on this
document to this office. If in doubt ASK.
- All structural timbers to be tanalised or similar
approved treatment.
- All Dimensions in this document are structural
dimensions and do not allow for thickness of finishes.
25 1887
JW
1:100, 1:50
APRIL
2025
S-01
S-01
4 740
2 840
4 255
4 255
5 000
5 000
5 000
5 000
8 910
OFFICE
WC
WC
STORE
STORE
WAREHOUSE
FLOOR
SHOP FLOOR
(NOT SURVEYED)
SHOP FLOOR
(NOT SURVEYED)
UP
MEZZANINE OVER
SHADED AREA
up
E
SD
EL
EL
S-01
S-01
3 740
1 800
STORE
LANDING
REHANG DOOR
TO OPEN AS
SHOWN
NEW
MEZZANINE
STORE
FD30
NEW
DOOR
NEW SHOP FLOOR
STOCKING DOOR
FD30
SHOP FLOOR
(NOT SURVEYED)
Guarding to mezzanine store floor set min 1100mm high
up
new mezzanine floor level to
match the floor level of the
neighbouring mezzanine floor in
shop unit
down
down
2 630
2 950
1 100
STORE
STORE
OFFICE
W.C.
WAREHOUSE
new mezzanine floor level to
match the floor level of the
neighbouring mezzanine floor in
shop unit
guarding to new mezzanine floor
area with open gates for loading
N
E
EL
SD
EL
EL
Ground Floor
1:100
First Floor
1:100
S-01 Section
1:100
Rev:
.
NOTES:
NOTE: THE ELEVATIONS ARE
UNAFFECTED BY THE MEZZANINE
WORKS.
NOTE: THIS DRAWING HAS BEEN
PRODUCED TO OBTAIN STATUTORY
PLANNING APPROVAL ONLY AND
SHOULD NOT BE READ AS A
WORKING DRAWING.
FIRE LEGEND:
Emergency Lighting to comply with
B.S. 5266 Part 1:1999
Break Glass Call Point for fire Alarm
System.
6 Litre AFFF Fire Extinguishers with
protective cover mounted on bracket
with handle 1 metre above the floor
level performance rating of not less
than 13A as specified in B.S.
5423:1987.
Automatic self contained mains
operated smoke dector alarm system
to be designed, installed and serviced
in accordance with the
recommendations of B.S. 5839 Part
1:2002.
Wall mounted illuminated Emergency
Exits signs to comply with B.S. 5499.
Internal doors marked thus 'FD30' are
to be 1⁄2 hour fire resistant doors to be
hung on self closing rising butt hinges.
Doors to be set in rebated fire check
frames with intumescent strips.
FD30