Loading document...
==== PAGE 1 ====
up up ENTRANCE HALL RETAIL UNIT STORES up W.C RETAIL UNIT SHED YARD YARD up PORCH vent 1113 1113 ramp up ramp up SVP up down down HALL C'UPD LOBBY STAFF ROOM W.C W.C FLAT ROOF up up LANDING LANDING FLAT ROOF down RETAIL UNIT LOBBY GALLEY SVP 8 14 Store Falcons Nest 7 STATION ROAD 1 11 Asahi Post Office House 9 13 15 17 1050 1340 2945 6300 1100 1050 900 up down LIVING ROOM KITCHEN BATHROOM UTILITY AREA BEDROOM LANDING LANDING down STUDY Drawing Name Drawing no. Revision Status Project Site Client ArchTec (IOM) Ltd. The Architectural Studio 7 Olafs close Douglas Isle of Man Date Scale e: [email protected] t: 01624 622122 m: 07624 498099 IM2 7AR January 2025 Varies @ A1 1700 - 3 w: www.archtecarchitectural.com © copyright - Reproduction of any element contained within this drawing is prohibited without written approval of the owners : ArchTec (IOM) Ltd THIS DRAWING IS PREPARED FOR APPROVAL PURPOSES ONLY. Written dimensions to be taken in preference to those scaled & should be verified on site & confirmed in advance of any site works / fabrication Rev Date Initial Comment . . . . Planning Submission Fistard Property Investments Ltd A P P L I C A T I O N S I T E G R O U N D F L O O R P L A N 1 : 1 0 0 S I T E P L A N 1 : 5 0 0 F I R S T F L O O R P L A N 1 : 1 0 0 Proposed Alterations to commercial building 11 Station Road Port Erin IM9 6AE R E A R E L E V A T I O N 1 : 1 0 0 F R O N T E L E V A T I O N 1 : 1 0 0 S I D E E L E V A T I O N 1 : 1 0 0 create new access to building from Station Road - to serve existing first floor retail / offices & new dwelling door to be recessed in line with door to retail unit first floor to be retained for use & linked to ground floor retail unit ELEVATIONS DRAWN FOR REFERENCE : NOT TO DETAILED SURVEY S C A L E B A R 1 : 1 0 0 remove door opening & wall up to match render & masonry paint finish remove existing timber infill within external wall & rebuild in masonry construction to match - to accept wall vent raise sill level of existing window & fit new Upvc window to match those existing refer to spec within existing window aperture S E C O N D F L O O R P L A N 1 : 1 0 0 raise sill level of existing window & fit new Upvc window to match those existing refer to spec within existing window aperture remove existing infill within external wall & rebuild in masonry construction to match - to accept wall vent remove door opening & wall up to match render & masonry paint finish As Proposed - Minor Changes create new access to building from Station Road - to serve existing first floor retail / offices & new dwelling door to be recessed in line with door to retail unit raise sill level of existing window & fit new Upvc window to match those existing refer to spec within existing window aperture
Copyright in submitted documents remains with their authors. Request removal