Existing stone wall
Box gutter made from 2mm alluminium
sheet. Nominally 165 x100 TBC by
contractor following site measure.
Cross brace, fully welded to box
gutter. Spaced at 200 c/c
Gutter strap to extend a minimum
of 2 battens under the tiles.
To be secured to rafters with
Stainless steel screws. Size TBC
once preliminary investigations
confirm makeup of roof structure
Build-Lite, Stone-Coat moulding to
manufacturers design and
specification and to be fixed to the wall
in accordance with Build-Lite
specification. Joints at approximately
1M
Moulding fixed to the gutter in
accordance with Build-Lite
specification and mechanical fixings
Existing roof slates to be
removed to facilitate review of
roof and wall structure under
prior to procurement of gutter
Plastic packer to suit if required
Nominally 10mm render band
Existing profile
Section A - Typical Section of Gutter
and Cornice/Parapet
Scale 1:5
General Notes
- BB Consulting drawings are to be read in conjunction
with the structural preliminaries, relevant specifications,
architectural and services drawings, including approved
builder's working drawings.
- Contractor to review all drawings and specifications and
notify lead designer of any discrepancies.
- All dimensions are in millimetres, unless noted
otherwise.
- Figured dimensions to be taken from the Architect's
drawings only. Do not scale from the drawings or
computer digital data.
- See Architect's drawings for setting out dimensions,
surface finishes and ALL other non-structural details.
- All dimensions to be checked on site. Engineer to be
informed immediately of any discrepancies before work
proceeds.
- Notify the Engineer prior to commencement of works if
ground conditions are found to be poor.
- Unless noted otherwise all standard door and window
lintels to be specified by the Architect.
- All nuts and bolts to be grade 8.8 to BS EN 20898
unless noted otherwise. Bolts to be Zinc electroplated
for internal use and spun hot dip galvanised for external
use.
- Any temporary works required are the responsibility of
the main contractor.
11.Contractor to liaise with Statutory Undertakers prior to
undertaking works which impact on existing
infrastructure or watercourses.
- Any services passing through structure to be isolated
and protected in accordance with the Service Engineer's
requirements.
Key:
Extent of new rain water gutter
Extent of new cornice/parapet
Downspout (110Ø). Cranked
under parapet to align to gully
Cornice/parapet mitered and
returned around downspout
to building
Downspout (110Ø)
George Hotel
Bank
The Parade
A
A
New box gutter and extent of
proposed Cornice/Parapet
.
Gutter Extent to
Front Elevation
Scale 1:50
Rev. Drn. Ckd. Date / Description
10cm - Caution as distortion can occur.
Original Size
10 cm
Job Title:
Drawing Status:
Scales @ A1:
Checked By:
Drawn By:
Authorised By:
Drawing Title:
Rev:
Drawing No:
Job No:
A1
BB Consulting Engineers Limited,
10 Myrtle Street,
t: 01624 664242
Douglas, Isle of Man,
e: [email protected]
IM1 1ED
w: bbconsulting.co.im
24-086
George Hotel, Castletown
100
Gutter Detail Section
AS SHOWN
MJ
CF
NQ
PLANNING