Loading document...
==== PAGE 1 ====
g KITCHEN LIVING ROOM PORCH BEDROOM BEDROOM BEDROOM HALL 60.35 PANTRY BEDROOM 4722 13151 2850 WELL DSD DSD HD ENSUITE 1226 2997 8572 TERRACE Havensea Fairy Cottage Filling Station y Inglenook The Cliffs Aysgarth Halt hie-My-Chree Cois nk rrey Fairy Cottage Ny-Creggan Cliffside 2100 1048 625 4716 S C A L E B A R @ 1 : 1 0 0 G R O U N D F L O O R P L A N 1 : 1 0 0 Drawing Name Drawing no. Revision Status Project Site Client ArchTec (IOM) Ltd. The Architectural Studio 7 Olafs Close Douglas Isle of Man Date Scale e: [email protected] t: 01624 622122 m: 07624 498099 IM2 7AR As Proposed March 2024 Varies @ A2 1647 - 10 w: www.archtecarchitectural.com © copyright - Reproduction of any element contained within this drawing is prohibited without written approval of the owners : ArchTec (IOM) Ltd THIS DRAWING IS PREPARED FOR APPROVAL PURPOSES ONLY. Written dimensions to be taken in preference to those scaled & should be verified on site & confirmed in advance of any site works / fabrication Rev Date Initial Comment . . . . Planning Submission Proposed Extensions & Alterations to Dwelling Mr Stephen Finnegan Inglenook Fairy Cottage Laxey IM4 7BR B L O C K P L A N 1 : 5 0 0 F R O N T E L E V A T I O N 1 : 1 0 0 R E A R E L E V A T I O N 1 : 1 0 0 S I D E E L E V A T I O N 1 : 1 0 0 doors within bedroom to allow safe passage in the event of fire well to be retained & exposed within room - ground floor detail to Structural Engineer's appraisal move door opening to access kitchen & rebuilt area steel roof beams / frame to be designed by Structural Engineer panel of dark colour composite cladding boards roof tiles to match existing dwelling velux roof windows on rear section of roof render & masonry paint to match existing dwelling existing door opening to access proposed bedroom remove existing steps upvc windows to match roof tiles to match existing dwelling velux roof windows panel of dark colour composite cladding boards render & masonry paint to match existing dwelling stone facing panels render & masonry paint to match existing dwelling existing footprint to be demolished shown dotted - appraisal by Structural Engineer existing footprint to be demolished shown dotted - existing retaining wall below rear ground level retained appraisal by Structural Engineer liase with service provider for working in close proximity to over head cables existing green house position new surface water drainage - being that the proposals replaces an existing building on a similar footprint - method of dispersion remains as existing public sewer exists on site - liase with MUA for building in close proximity to sewer line as discussed with Aisha Slinger doors within bedroom to allow safe passage in the event of fire existing footprint to be demolished shown dotted - appraisal by Structural Engineer tanked retaining wall to rear of building appraisal by structural engineer structure built to that of the existing ensure no projection beyond boundary structure built to that of the existing ensure no projection beyond boundary extent of structure to be re-built existing dwelling existing gardens proposals do not influence vehicular access or parking provision within the site upvc rainwater goods to match existing dwelling composite decked area fronting doors with steps to garden to be removable should drain access ever be required M.E.R lines & revetment works approved floor level raised by approx 620mm to compensate for adjusted ground levels at rear of site for M.E.R works approved floor level raised by approx 620mm to compensate for adjusted ground levels at rear of site for M.E.R works S.S & glass ballastrade over decking to guard against falling composite decked area fronting doors with steps to garden to be removable should drain access ever be required composite decked area fronting doors with steps to garden to be removable should drain access ever be required approved floor level raised by approx 620mm to compensate for adjusted ground levels at rear of site for M.E.R works F.F.L @ 61.02 as existing Sun Lounge F.F.L @ 61.02 as existing Sun Lounge approved floor level raised by approx 620mm to compensate for adjusted ground levels at rear of site for M.E.R works S.S & glass ballastrade over decking to guard against falling approx level M.E.R lines existing footprint to be demolished shown dotted - existing retaining wall below rear ground level retained appraisal by Structural Engineer maintain existing rear retaining wall built at a splay demolish over rear ground level & cap to accept new horizontal beam to accept new wall
Copyright in submitted documents remains with their authors. Request removal