==== PAGE 1 ====
front (north-west) elevation
end (south-west) elevation
end (north-east) elevation
rear (south-east) elevation
Finishes
Walls - red and buff facing brick to match with the adjacent building,
(Hazel Court).
Doors - mid grey steel doors with access control fob.
Serving hatch - polyester powder coated steel roller shutter operated
from inside.
Roof - colour coated steel with tile profile in colour mid grey.
Eaves - polyester powder coated aluminium fascias and soffits.
Rainwater goods - polyester powder coated aluminium square down
pipes and box gutters. down pipes to be fitted flush to the wall so that
they are vandal resistant and anti-climb.
400
section A-A
changing
room 2
showers
wheelchair
accessible wc
service void
flue
plant room
changing
room 2
showers
showers
new 1800mm brush finish concrete path
changing
room 4
officials changing
room 2
ground floor plan
A
A
officials changing
room 1
wc
shower
serving
hatch
showers
wc
changing
room 3
shower
showers
changing
room 1
wc
wc
storage
wc
(m)
wc
(f)
dis wc
wc
wc
storage
rwp
rwp
rwp
rwp
18.9M
10.6M
3M
4M
- 100.72
- 100.76
SPRINGFIELD ROAD
- 100.00
- 99.93
100.06 +
- 100.15
- 100.36
- 100.79
new changing facilities
existing access track
new 1800mm brush finish concrete path
existing timber boarded boundary fence
grass
existing metal (boundary) fence retained
grass
grass
new surface water drainage
key
new foul drainage
- 100.47
- 100.02
100.35 +
playing fields (football pitches)
existing foul manhole
4M
99.66 +
99.77 +
99.82 +
existing metal access gate retained
existing metal fence retained
discharge to existing foul
public drain
discharge to existing surface
water public drain
18.9M
10.6M
6.6M
10.5M
project title
drawing title
rev date
APPROVED REPLACEMENT CHANGING ROOMS
PA 22/01456/B
AT PULROSE FOOTBALL CLUB, SPRINGFIELD
ROAD, DOUGLAS
FOR DOUGLAS BOROUGH COUNCIL
notes
FRS\ULJKW22 McGarrigle Architects Ltd.
1 contractors must verify dimension before
commencing shop or site work.
2 written dimensions to be taken in
preference to scaled dimensions.
3 This drawing has been prepared for
Statutory Planning Application purposes
only and is not to be interpreted as a full
working construction drawing.
date
01
job no
June 2022
1874
scale
client no
1:100 @A1
P-02
chkd by
drg no
drn by
fd
rev
NMG
B
A
updated to suit clients
recommendations, drainage updates,
external vents / flue added
08.09.2022
B
updated to structural engineers
drainage plan, red line updated to suit,
dimensions added
16.11.2022
APPROVED PLANNING APPLICATION
REF: PA 22/01456/B