Loading document...
==== PAGE 1 ====
2340 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 30. 29. 28. 27. 26. 25. 24. 23. 22. 21. 20. 16. 17. 17. 1100 671 719 1150 900 950 700 300 3 3 ,5 ° 2317 1922 2317 2498 2565 2498 671 1150 940 1150 940 2381 2199 2191 2199 465 325 325 1903 6558 1374 3428 3297 6835 6076 2429 1361 900 900 640 2054 3143 1102 940 3740 1420 900 1420 2779 1102 940 2409 800 2096 1600 2409 800 2096 1600 1010 14820 9781 3428 2054 640 900 1240 1699 1699 2077 2063 22. 28. 29. 30. 27. 26. 25. 16. 17. 18. 19. 15. 964 2767 3716 3367 1610 600 600 3090 1970 1700 600 3090 3428 1486 1135 3104 1061 3853 3853 1870 1870 SD SD 1135 1610 1700 600 955 2083 1775 1169 600 3090 4111 2649 1870 1970 600 3252 2063 1775 1486 3249 2972 3428 22. 28. 29. 30. 27. 26. 25. 16. 17. 18. 19. 15. TYPE B. TYPE C. TYPE B. TYPE C. 16/2557/06F 1:50 @A1 Second Floor Plan and Sections as Proposed Proposed Redevelopment of Shore House and Boathouse Shore Road Port Erin CJS Tel. 01624-621375 Fax. 01624-628465 e-mail. [email protected] Ellis Brown Architects Interior Designers Surveyors Queens Promenade Douglas Isle of Man, IM2 4NR 12 Strathallan Crescent Intelligent Developments Ltd SECOND FLOOR PLAN - 1:50 SECTION A. - A. - 1:50 SECTIONAL ELEVATION B. - B. - 1:50 rwp rwp rwp rwp rwp MJ MJ SD The power supply for the smoke alarm system should be derived from the buildings mains electrical supply. The mains supply to the smoke alarm(s) should comprise a single independant circuit at the dwellings main distribution board. FIRE LEGEND FD 30 Half-hour fire resisting door, self-closing into 25mm rebates. Area to be covered by domestic smoke detector and alarm. SC Door to be fitted with approved self-closer. Cavi240 300 x 110 type SAF Vertical Cavity Barrier by Cavity Trays of Yeovil. HD Area to be covered by domestic heat detector. MJ April. 2017 Bedroom Bedroom Bedroom 2 Bedroom 1 Bedroom 2 Bedroom 1 s/vp s/vp s/vp s/vp s/vp stub stack stub stack s/vp rwp / balcony outlet rwp / balcony outlet rwp / balcony outlet rwp rwp / balcony outlet 2 dpc dpc dpc dpc dpc dpc Kitchen Bedroom Bedroom Kitchen Hall Cloaks Bath Bath Living Room / Dining Bedroom Terrace Utility Terrace Terrace dpc / cavity tray dpc / cavity tray dpc / cavity tray dpc / cavity tray dpc / cavity tray dpc / cavity tray dpc / cavity tray dpc / cavity tray B. B. Utility Utility A. A. dpc / cavity tray dpc dpc dpc Bath dpc dpc dpc FD 30 FD 30 FD 30 FD 30 FD 30 FD 30 A June 2017 Emergency egress window indicated to rear terrace areas; Cavity wall construction note amended to show 125mm wide cavity not 110mm as previously; FR30 fire doors indicated to Second Floor Bedrooms; Sound insulation indicated to timber framed partitions between bedrooms; Note added concerning temperature control of hot water to baths. egress window egress window egress window egress window egress window egress window egress window egress window egress window egress window B Jan. 2018 Cavity wall note amended to show dry lining internally in lieu of gypsum plaster. proposed ground floor drainage amended following discussions with Manx Utilities, paving slabs on adjustable pedestals to balcony areas indicated to sections. Reinforced concrete slab foundation amended in-line with Structural Engineers drawings. FFL = 5.990 FFL = 5.990 FFL = 5.830 FFL = 5.830 FFL = 5.990 FFL = 8.530 FFL = 11.230 C Feb. 2018 Retaining / boundary wall to rear bank increased slightly in height and glass balustrade removed. dpc D April. 2018 Cavity walls amended to 325mm wide as described in construction note. E Feb. 2020 Cavity walls amended to 325mm wide as described in construction note; Section A.-A. amended to show cavity wall to rear of Utility Room, perforated land drain to base of retaining wall omitted; Section B.-B. amended to show insulated cavity wall to gable garage; second floor plan amended to show position of retaining wall and repositioning rooflights. F Feb. 2021 Section A-A amended along with Second Floor plan to show as built; Roof insulation amended. En-Suite En-Suite 2
Copyright in submitted documents remains with their authors. Request removal