**Document:** Philips Lighting Report
**Application:** 09/00340/B — Creation of a football ground with associated facilities to include club house, parking, tractor shed, drainage system, landscaping, lighting and fencing, including new vehicular access with entrance from Main Road and controlled railway barrier crossing
**Decision:** Permitted
**Decision Date:** 2009-08-17
**Parish:** Arbory
**Document Type:** report / planning_statement
**Source:** https://planningportal.im/a/63329-colby-field-421449-dwelling-outbuilding/documents/1560372

---

# Philips Lighting Report

## Colby AFC Isle of Man

[Table omitted in markdown export]

RECEIVED ON
**17 JUN 2009**
DEPT OF LOCAL GOVERNMENT
AND THE ENVIRONMENT

Calculations have been prepared for the following areas:-

- Car Park
- Access Road

Parameters taken are as follows:-

- Maintenance Factor of 0.85
- Column Height of 6M
- Lantern inclination 5 degrees
- Lamp Positions 3 & 5

Date: 29.01.2009
Operator: Anthony Cox

Operator Anthony Cox
Telephone
Fax
e-Mail Anthony.Cox@Philips.com

## Colby AFC Isle of Man / Luminaire parts list

12 Pieces Philips IRIDIUM SGS252 FG 1xCDO-TT70W/828 CON CR P3
Article No.:
Luminaire Luminous Flux: 6300 lm
Luminaire Wattage: 86.2 W
Luminaire classification according to CIE: 100
CIE flux code: 41 81 99 100 81
Fitting: 1 x CDO-TT70W (Correction Factor 1.000).

![A low-resolution close-up image showing a white, curved outdoor light fixture or lamp post against a blue background.](https://images.planningportal.im/2009/06/308274.jpg)

27 Pieces Philips IRIDIUM SGS252 FG 1xCDO-TT70W/828 CON CR P5X
Article No.:
Luminaire Luminous Flux: 6300 lm
Luminaire Wattage: 86.2 W
Luminaire classification according to CIE: 100
CIE flux code: 42 80 99 100 81
Fitting: 1 x CDO-TT70W (Correction Factor 1.000).

![A rough, hand-drawn sketch depicting the outline of a plot of land or site boundary.](https://images.planningportal.im/2009/06/2273524.jpg)

Operator Anthony Cox
Telephone
Fax
e-Mail Anthony.Cox@Philips.com

## Philips IRIDIUM SGS252 FG 1xCDO-TT70W/828 CON CR P3 / Luminaire Data Sheet

Luminaire classification according to CIE: 100
CIE flux code: 41 81 99 100 81

Luminous emittance 1:

Due to missing symmetry properties, no UGR table can be displayed for this luminaire.

## Philips IRIDIUM SGS252 FG 1xCDO-TT70W/828 CON CR P5X / Luminaire Data Sheet

Luminaire classification according to CIE: 100
CIE flux code: 42 80 99 100 81

Due to missing symmetry properties, no UGR table can be displayed for this luminaire.

Operator Anthony Cox
Telephone
Fax
e-Mail Anthony.Cox@Philips.com

### Exterior Scene 1 / Luminaires (layout plan)

Scale 1 : 1733

### Luminaire Parts List

Page 5

[Table omitted in markdown export]

![This image displays a technical cross-section or profile drawing showing ground levels and distances with numbered markers along a boundary line.](https://images.planningportal.im/2009/06/2273514.jpg)

Operator Anthony Cox
Telephone
Fax
e-Mail Anthony.Cox@Philips.com

### Exterior Scene 1 / False Colour Rendering

![Technical lighting calculation diagram showing illuminance levels (lux) on a proposed football ground site plan with a color scale bar.](https://images.planningportal.im/2009/06/2273515.jpg)

![A site plan showing a long, narrow plot of land with a rectangular building footprint and a color-coded legend at the bottom.](https://images.planningportal.im/2009/06/308285.jpg)

Operator Anthony Cox

Telephone

Fax

e-Mail Anthony.Cox@Philips.com

Exterior Scene 1 / Car Park / Surface 1 / Isolines (E)

Values in Lux, Scale 1 : 1239

Position of surface in external scene:

Marked point:

(1264.395 m, 848.945 m, 0.000 m) ![A technical site plan displaying topographical contour lines and elevation levels for a land plot.](https://images.planningportal.im/2009/06/2273516.jpg) Grid: 128 x 128 Points

E By [lx] 21

E min [lx] 3.83

E max [lx] 51

u0 0.184

E min / E max 0.075

Operator Anthony Cox

Telephone

Fax

e-Mail Anthony.Cox@Philips.com

Exterior Scene 1 / Access Road / Surface 1 / Isolines (E)

![A technical engineering drawing showing a longitudinal section or profile of a winding path or road with contour lines and elevation markers.](https://images.planningportal.im/2009/06/2273576.jpg)
Position of surface in external scene:
Marked point:
(1423.583 m, 889.559 m, 0.000 m)

Values in Lux, Scale 1 : 1279

Grid: 128 x 128 Points

E_av [lx]
18

E_min [lx]
4.48

E_max [lx]
38

u0
0.253

E_min / E_max
0.119

Colby AFC Isle of Man
• Philips IR100UM SG1252 FG (vC80-1170V/928 CON CR P3 (tVC80-1170V)
• Philips IR100UM SG1252 FG (vC80-1170V/928 CON CR PS4 (tVC80-1170V))

Isolines
- 53 lx
- 160 lx
- 250 lx
- 350 lx
- 450 lx

RECEIVED ON
17 JUN 2009
Dept. OF LOCAL GENERATION
AND THE ENVIRONMENT

---

*Data sourced from the Isle of Man public planning register under the [Isle of Man Open Government Licence](https://www.gov.im/about-this-site/open-government-licence/).*
*Canonical page: https://planningportal.im/a/63329-colby-field-421449-dwelling-outbuilding/documents/1560372*