**Document:** Planning Statement
**Application:** 25/90779/B — Conversion of existing mill building with construction of extension to create new dwelling
**Decision:** Permitted
**Decision Date:** 2025-10-30
**Parish:** Marown
**Document Type:** report / planning_statement
**Source:** https://planningportal.im/a/33185-crosby-old-mill-building-conversion-extension/documents/1073758

---

# Planning Statement

## Planning Statement

![drawing from page 1](https://images.planningportal.im/2025/08/7098685.jpg)

### Proposed conversion, alterations and extension of existing Mill Building to create a new dwelling at Rock Farm, Main Road, Crosby, Marown, IM4 2DW

6 August 2025

##### Index:

- 1. Site.
- 2. Pre-Application Advice.
- 3. Planning History.
- 4. Proposals.
- 5. Previous Approvals.
- 6. Access.
- 7. Services.
- 8. Trees/Landscaping.
- 9. Bats & Birds.
- 10.Sustainability.

#### 1. Site

![An aerial map view showing a rural landscape with green fields and a road, highlighting a specific building labeled 'Mill Building' with a red arrow.](https://images.planningportal.im/2025/08/7098687.jpg)

![A site location map displaying field boundaries and roads with a red arrow pointing to the existing mill building.](https://images.planningportal.im/2025/08/7098688.jpg)

The proposed site is an Old Mill Building located at Rock Farm in Crosby oﬀ the main A1 Peel Road and is in the Parish of Marown. Google Map above shows the location of the Old Mill Building in red. The OS Map above shows the location of the Old Mill Building in red.

The old County Series Map above shows the location of the Old Mill Building in red.

The site comprises of the Old Stone Mill Building, subject to this application, remnants of a steel portal frame dutch agricultural barn, see drawing number 25 1880/15 for further details. The main detached farmhouse. A series of detached stone barns and a large steel portal frame agricultural barn. All accessible oﬀ an existing access lane oﬀ the main A1 Peel Road. Visibility aﬀorded to the existing vehicle access oﬀ the main A1 Peel Road is very good. The Old Mill Building is not visible from the main A1 Peel Road.

A series of Site Photographs, numbered 25 1880/SP, show all the existing buildings on the site described above.

#### 2. Pre-Application Advice:

A meeting was held on site with the Planning Oﬃcer, Chris Balmer, on Friday 7th March 2025 to walk the site and discuss the initial design concept approach for the proposals.

A follow on meeting, with Mr Balmer, was carried out at the Planning Department on Thursday 24th July 2025 to discuss the initial Draft Proposals, with some minor alterations discussed at that meeting. These minor alterations have been incorporated within the ﬁnal submitted design.

![This image shows a historical map or site plan highlighting a 'MILL BUILDING' with a red arrow, surrounded by fields and landmarks like St. Trinians Chapel.](https://images.planningportal.im/2025/08/7098689.jpg)

#### 3. Planning History:

![Architectural ground floor plan showing the layout of rooms including living, dining, kitchen, and study areas within a converted mill building.](https://images.planningportal.im/2025/08/7098690.png)

![This is an architectural ground floor plan drawing showing the layout of a converted mill building with an extension, including rooms like a kitchen and garage.](https://images.planningportal.im/2025/08/7098691.png)

The site is subject to a series of previous planning applications, which are as follows;

- • 00/02227/B: Approval in Principle for a replacement dwelling- Approved 03/05/01.
- • 02/00839/B: Replacement dwelling and conversion of Mill Building- Approved 31/10/02. ( See attachments below).
- • 03/00347/B: Conversion of barns to 2 dwellings- Approved 16/10/03.

Ground Floor Plan Approved under P.A. No- 02/00839/B.

First Floor Plan Approved under P.A. No- 02/00839/B.

Elevations Approved under P.A. No- 02/00839/B.

![The image displays architectural floor plans for a mill conversion, including a first-floor plan with bedrooms and a lower-level plan featuring a garage and living space.](https://images.planningportal.im/2025/08/7098692.png)

![This image displays a black and white architectural floor plan of a residential property. It outlines the layout of multiple bedrooms, bathrooms, and a central gallery area with a spiral staircase.](https://images.planningportal.im/2025/08/7098693.png)

![Architectural elevations showing the North and South facades of a building conversion project with an extension.](https://images.planningportal.im/2025/08/7098696.png)

![A black and white architectural line drawing showing a building floor plan or elevation with multiple windows and doors.](https://images.planningportal.im/2025/08/7098698.png)

![Architectural elevation drawing showing a row of windows and a central arched doorway.](https://images.planningportal.im/2025/08/7098699.png)

Site & Location Plans Approved under P.A. No- 02/00839/B.

#### 4. Proposals:

The proposals submitted have not changed from those discussed with the Planning Oﬃcer, Chris Balmer, on Thursday 24th Jury 2025.

The submitted Survey Drawings numbered 25 1880/02 to 05 show the Floor Plans, Elevations, Sections and 3D Models of the existing Old Mill Building.

![This image displays a planning document page featuring a site location map with a thick boundary line at the top and a detailed site plan with contours and building footprints below.](https://images.planningportal.im/2025/08/7098700.jpg)

![An inverted black and white image showing a site location plan with property boundaries and a building labeled 'Rack Farm'.](https://images.planningportal.im/2025/08/7098701.png)

The submitted proposed drawings numbered 25 1880/06 to 13 & 19 show the proposed Floor Plans, Roof Plan, Elevations, Sections and 3D Models of the proposed converted, altered and extended Old Mill Building to create a new dwelling.

The proposals show the ground ﬂoor level of the existing Old Mill Building converted into a Garage, Plant Room and Media/Cinema Room, utilising all existing openings/apertures.

A new door would be located in the South-West gable end of the building to provide direct external access into the Garage.

Another external door would be located in the North-West elevation of the building to provide direct external access out to the existing lean-to outlet which would be converted into a semi-open Car Port. A new metal external staircase would be installed to provide access up to a new ﬂat roof Balcony area.

The upper ﬁrst ﬂoor level of the existing Mill Building would be converted into open plan living space, comprising of Living, Dining, Breakfast and Kitchen zones. Again all existing openings/ aperture would be utilised with a set of new double doors formed in the North-West elevation, providing direct access out onto the new ﬂat roof Balcony Area.

A series of new conservation style roof lights would be installed in the existing North-West roof slope to provide additional natural sun light down into the open plan living space.

The proposed extensions would comprise of a single storey outlet, built to follow the site topography and stepping up the site in height, to follow the existing site contours/levels.

The extensions would provide a central Entrance Hallway with Utility Room and W.C. The Entrance Hallway would lead out onto a Covered Rear Patio Area which would be linked with the proposed Rear Balcony.

The Entrance Hallway would lead into the open plan living space created in the upper ﬂoor level of the existing Old Mill Building.

A new rear Hallway would lead past a Snug and large Family Bathroom and into the Bedroom wing outlet of the proposed extensions.

The Bedroom wing outlet would be built exactly on the footprint of the previous large steel portal frame Dutch Barn. See submitted drawing number 25 18880/15, for further details. This wing would provide four Bedrooms in total. A Master and Guest Bedroom 2 suite with Bedrooms 3 and

- 4 utilising the Family Bathroom facilities.

A Covered Front Patio Area would be provided oﬀ the Master Bedroom with large bi-folding/sliding door units leading out to the external Patio Area.

The external ﬁnishes would comprise of traditional natural materials, that will weather and bed down within the site over time. These materials would be used in a contemporary form. See submitted Finishes Schedule, drawing number 25 1880/25, for further details.

- 5. PREVIOUS APPROVALS:

The proposals submitted utilise Housing Policy 11 of The Isle of Man Strategic Plan 2016, which states;

8.10 Conversion of Rural Buildings to Dwellings

- 8.10.1 Throughout the countryside, there are examples of buildings which are no longer suitable or needed for their originally intended use, but which are of sufficient quality or interest to warrant retention and re-use.
- 8.10.2 Conversion of such buildings into dwellings can make a useful contribution to the housing stock, ensure retention of our built heritage, and improve the appearance of what might otherwise become derelict fabric. The following policy is therefore appropriate:

Housing Policy 11: Conversion of existing rural buildings into dwellings may be permitted, but

only where:

- (a) redundancy for the original use can be established;
- (b) the building is substantially intact and structurally capable of renovation;
- (c) the building is of architectural, historic, or social interest;
- (d) the building is large enough to form a satisfactory dwelling, either as it stands or with modest, subordinate extension which does not affect adversely the character or interest of the building;
- (e) residential use would not be incompatible with adjoining established uses or, where appropriate, land-use zonings on the area plan; and
- (f) the building is or can be provided with satisfactory services without unreasonable public expenditure.

Such conversion must:

- (a)where practicable and desirable, re-establish the original appearance of the building; and
- (b) use the same materials as those in the existing building.

Permission will not be given for the rebuilding of ruins or the erection of replacement buildings of similar, or even identical, form.

Further extension of converted rural buildings will not usually be permitted, since this would lead to loss or reduction of the original interest and character.

Some recent examples of previous approvals that have utilised the same Planning Policy are:

- • P.A. No- 23/00711/B- Approved- 20/10/23.

39.90

39.87

Grass

Soakaway/ French Drains

40.26

###### 40.40

40.45

Grass

40.57

39.78 39.73

38.63

Klargester Bio-Disc

Sample Chamber

38.39

40.22

39.78

39.97

FWIC

38.41

5,650

A-A

39.05

Brash

B-B

38.93

Steel SHS post

Grass

Steel Rafter Sections

39.31

LIVING AREA

38.87

39.06

|FFL 39.200|
|---|

Steel SHS post

1,675

Eaves

38.50

42.72

41.01

38.84

39.21

38.96

FWIC

39.10

39.07

2,450

40.02

40.12

39.23

42.57

41.31

39.11

HALLWAY

40.52

Steel SHS posts

Grass

WTop

B-B

WTop

42.55

44.22

Steel SHS post

43.07

39.28

Ridge

40.06

41.02

44.51

41.06

39.89

39.95

41.08

39.13

1,525

Steel SHS post

41.84

38.46

39.51

39.47

41.00

42.98

40.20

Steel SHS posts

43.25

41.37

Steel SHS posts

41.54

KITCHEN AREA

41.40

42.71

41.23

39.66

40.46

42.83

5,250

Head

Scrub

42.74

40.34 39.89

WTop

4,325

Steel SHS post

39.01

41.28

|FFL 39.200|
|---|

40.35

38.85

42.79

39.63

39.50

38.77

38.15

39.99

Sill

37.35

41.14

Steel SHS posts

39.69

38.70

Head

43.09

40.97

42.65

39.75

42.47 42.79

Sill

38.56

42.92

Head

WTop

40.33

38.54

39.62

A-A

ASHP

39.26

38.42

38.91

38.99 39.09

WTop

39.43 39.89

40.51

WTop

39.52

Scrub

40.48

Scrub

38.28

Scrub

39.93

40.07

40.01

40.05

40.30

40.36

40.44

Ground Floor Plan 1:50

General notes

- 1. This document and its design content is the copyright © property of Penketh Millar Ltd. and may not be reproduced in any way without the permission of Penketh Millar Ltd. It shall be read in conjunction with all other associated project information including models, speciﬁcations, schedules and related consultants documents.
- 2. Do not scale from documents, written dimensions to take preference at all times.
- 3. All dimensions & levels to be checked on site prior to construction or fabrication of any elements. Immediately report any discrepancies, errors or omissions on this document to this oﬃce. If in doubt ASK.
- 4. All structural timbers to be tanalised or similar approved treatment.
- 5. All Dimensions in this document are structural dimensions and do not allow for thickness of ﬁnishes.

###### Elevation Notes:

WALLS: Existing Manx stone walls to the remains of the Od Mill Building are to remain in place, including all existing window and door apertures, and to be structurally supported by a new steel frame installed within the footprint of the old building. Proposed cavity walls to the Living Area extension to be finished externally in minimum 200mm thick traditionally laid natural Manx stone work to be laid with concealed mortar joints. Proposed cavity walls to the central link Entrance Hallway to be finished externally in corten weathering steel cladding. The proposed SIPs/timber frame wall within the old mill building that project above the existing stone wall line to be finished externally in corten weathering steel cladding.

WINDOWS/DOORS: The proposed central Entrance Hallway door to be finished externally in corten weathering steel cladding to match the main walls. All other proposed window and doors to be light grey power coated aluminium/composite framed, double glazed units with opening lights as indicated on the elevations. The door units to the Living Area extension to be fitted with either bi-folding or sliding door units. The door/window units located in the corten steel cladding are to be fitted with projecting head/reveal/sill sections formed in corten weathering steel.

RAINWATER GOODS: The proposed surface water from the roof sections is to be collected in hidden guttering systems. Fitted with rainwater chains to be connected to back inlet gullies. Gullies to discharge to proposed soakaways or existing stream.

ROOF: Proposed roof sections to be finished externally in corten weathering steel cladding to match the main walls.

###### General Notes:

FIRE REGULATIONS: The proposed fire requirements for this type of residential development are covered under Approved Document B of the Building Regulations, including legislation for the installation of sprinkler systems and as such will be dealt with at the Building Regulation Submission Stage.

NOTE: This proposed drawing has been prepared to obtain statutory Planning approval only and should not be read as a full working drawing. The copyright of this drawing is the property of Penketh-Millar Ltd and may not be reproduced without their permission. Written dimensions to be used in preference to scaled dimensions at all times.

Purpose of Issue

###### Planning

23 West Quay Ramsey Isle of Man IM8 1DL

Tel: 01624 813219 / 814178 Fax: 01624 816436 penkethmillar@manx.net www.penkethmillar.co.uk

|Client<br><br>Mr & Mrs E. McDonnell|
|---|

Contract

Proposed conversion and extension of existing Old Mill Building to create new dwelling/Tourist Accommodation at land to rear of Ballacuberagh Cottage, Sulby Glen, Lezayre

Drawing Title

PROPOSED GROUND FLOOR PLAN Drawing Information Scales @ A1 Drawn by Drawing number Rev

Date

1:50 MAY CPP 22 1702 23

.

Approved Ground Floor Plan.

General notes

- 1. This document and its design content is the copyright © property of Penketh Millar Ltd. and may not be reproduced in any way without the permission of Penketh Millar Ltd. It shall be read in conjunction with all other associated project information including models, speciﬁcations, schedules and related consultants documents.
- 2. Do not scale from documents, written dimensions to take preference at all times.
- 3. All dimensions & levels to be checked on site prior to construction or fabrication of any elements. Immediately report any discrepancies, errors or omissions on this document to this oﬃce. If in doubt ASK.
- 4. All structural timbers to be tanalised or similar approved treatment.
- 5. All Dimensions in this document are structural dimensions and do not allow for thickness of ﬁnishes.

North-West Elevation 1:100 South-East Elevation 1:100

###### General Notes:

North-East Elevation 1:100

FIRE REGULATIONS: The proposed fire requirements for this type of residential development are covered under Approved Document B of the Building Regulations, including legislation for the installation of sprinkler systems and as such will be dealt with at the Building Regulation Submission Stage.

NOTE: This proposed drawing has been prepared to obtain statutory Planning approval only and should not be read as a full working drawing. The copyright of this drawing is the property of PenkethMillar Ltd and may not be reproduced without their permission. Written dimensions to be used in preference to scaled dimensions at all times.

South-West Elevation 1:100

A-A

WINDOWS/DOORS: The proposed central Entrance Hallway door to be finished externally in corten weathering steel cladding to match the main walls. All other proposed window and doors to be light grey power coated aluminium/composite framed, double glazed units with opening lights as indicated on the elevations. The door units to the Living Area extension to be fitted with either bi-folding or sliding door units. The door/window units located in the corten steel cladding are to be fitted with projecting head/reveal/sill sections formed in corten weathering steel.

B-B

ROOF: Proposed roof sections to be finished externally in corten weathering steel cladding to match the main walls.

N

Steel SHS posts Steel SHS post

B-B

2,300

Steel SHS post

Steel SHS post

Steel rafter sections

Steel U.B. ridge purlin

Steel SHS post

W

Steel SHS post

Purpose of Issue

1,925

###### Planning

Steel SHS post

BEDROOM

4,325

Steel SHS post

|FFL 41.800|
|---|

23 West Quay Ramsey Isle of Man IM8 1DL

Tel: 01624 813219 / 814178 Fax: 01624 816436 penkethmillar@manx.net www.penkethmillar.co.uk

Steel SHS posts

3D Visual Image No 1 NTS WALLS: Existing Manx stone walls to the remains of the Od Mill Building are to remain in place, including all existing window and door apertures, and to be structurally supported by a new steel frame installed within the footprint of the old building. Proposed cavity walls to the Living Area extension to be finished externally in minimum 200mm thick traditionally laid natural Manx stone work to be laid with concealed mortar joints. Proposed cavity walls to the central link Entrance Hallway to be finished externally in corten weathering steel cladding. The proposed SIPs/timber frame wall within the old mill building that project above the existing stone wall line to be finished externally in corten weathering steel cladding.

|Client<br><br>Mr & Mrs E. McDonnell|
|---|

A-A

RAINWATER GOODS: The proposed surface water from the roof sections is to be collected in hidden guttering systems. Fitted with rainwater chains to be connected to back inlet gullies. Gullies to discharge to proposed soakaways or existing stream.

Contract

Proposed conversion and extension of existing Old Mill Building to create new dwelling/Tourist Accommodation at land to rear of Ballacuberagh Cottage, Sulby Glen, Lezayre

First Floor Plan 1:50

Approved First Floor Plan, Elevations & 3D Model.

Drawing Title

PROPOSED F.F. PLAN & ELEVATIONS Drawing Information Scales @ A1 Drawn by Drawing number Rev

Date

1:50, 1:100 MAY CPP 22 1702 23

.

|Aerial photograph of all existing stone walls of the Old Mill Building.|
|---|

|Existing stone walls to the N-W & S-W elevations of the Old Mill Building.|
|---|

|Existing stone walls to the N-E & N-W elevations of the Old Mill Building.|
|---|

|Example of walls and roof finished in corten weathering steel cladding set inside an existing facade.|
|---|

General notes

- 1. This document and its design content is the copyright © property of Penketh Millar Ltd. and may not be reproduced in any way without the permission of Penketh Millar Ltd. It shall be read in conjunction with all other associated project information including models, speciﬁcations, schedules and related consultants documents.
- 2. Do not scale from documents, written dimensions to take preference at all times.
- 3. All dimensions & levels to be checked on site prior to construction or fabrication of any elements. Immediately report any discrepancies, errors or omissions on this document to this oﬃce. If in doubt ASK.
- 4. All structural timbers to be tanalised or similar approved treatment.
- 5. All Dimensions in this document are structural dimensions and do not allow for thickness of ﬁnishes.

WALLS: Existing Manx stone walls to the remains of the Od Mill Building are to remain in place, including all existing window and door apertures, and to be structurally supported by a new steel frame installed within the footprint of the old building. Proposed cavity walls to the Living Area extension to be finished externally in minimum 200mm thick traditionally laid natural Manx stone work to be laid with concealed mortar joints. Proposed cavity walls to the central link Entrance Hallway to be finished externally in corten weathering steel cladding. The proposed SIPs/timber frame wall within the old mill building that project above the existing stone wall line to be finished externally in corten weathering steel cladding.

WINDOWS/DOORS: The proposed central Entrance Hallway door to be finished externally in corten weathering steel cladding to match the main walls. All other proposed window and doors to be light grey power coated aluminium/composite framed, double glazed units with opening lights as indicated on the elevations. The door units to the Living Area extension to be fitted with either bi-folding or sliding door units. The door/window units located in the corten steel cladding are to be fitted with projecting head/reveal/sill sections formed in corten weathering steel.

|Example of walls and roof finished in corten weathering steel cladding, with traditional stone and large contemporary aluminium window/door units set within and existing stone facade|
|---|

South-West Elevation 1:100

ROOF: Proposed roof sections to be finished externally in corten weathering steel cladding to match the main walls.

|Example of walls and roof finished in corten weathering steel cladding, with traditional stone and large contemporary aluminium window/door units set within and existing stone facade|
|---|

North-East Elevation 1:100

RAINWATER GOODS: The proposed surface water from the roof sections is to be collected in hidden guttering systems. Fitted with rainwater chains to be connected to back inlet gullies. Gullies to discharge to proposed soakaways or existing stream.

|Example of walls and roof finished in corten weathering steel cladding, with traditional stone and large contemporary aluminium window/door units.|
|---|

|Example of rainwater chains.|
|---|

Purpose of Issue

23 West Quay Ramsey Isle of Man IM8 1DL

Tel: 01624 813219 / 814178 Fax: 01624 816436 penkethmillar@manx.net www.penkethmillar.co.uk

|Client<br><br>Mr & Mrs E. McDonnell|
|---|

Contract

Proposed conversion and extension of existing Old Mill Building to create new dwelling/Tourist Accommodation at land to rear of Ballacuberagh Cottage, Sulby Glen, Lezayre

Drawing Title

FINISHES SCHEDULE Drawing Information Scales @ A1 Drawn by Drawing number Rev

Date

1:100 MAY CPP 22 1702 23

.

Approved Finishes Schedule.

![A low-resolution photograph showing a dark green fence or wall in the foreground with trees and sky visible in the background.](https://images.planningportal.im/2025/08/7098704.jpg)

###### • P.A. No- 23/00679/B- Approved 19/10/23.

![drawing from page 12](https://images.planningportal.im/2025/08/7098709.jpg)

General notes

- 1. This document and its design content is the copyright © property of Penketh Millar Ltd. and may not be reproduced in any way without the permission of Penketh Millar Ltd. It shall be read in conjunction with all other associated project information including models, speciﬁcations, schedules and related consultants documents.
- 2. Do not scale from documents, written dimensions to take preference at all times.
- 3. All dimensions & levels to be checked on site prior to construction or fabrication of any elements. Immediately report any discrepancies, errors or omissions on this document to this oﬃce. If in doubt ASK.
- 4. All structural timbers to be tanalised or similar approved treatment.
- 5. All Dimensions in this document are structural dimensions and do not allow for thickness of ﬁnishes.

Blocked up window Blocked up door Blocked up door North-West Elevation 1:100 South-East Elevation 1:100 North-East Elevation 1:100 South-West Elevation 1:100

103.93

###### Elevation Notes:

Head

Ridge

106.08

109.06

WALLS: External cavity walls to the proposed extensions to be finished in untreated, good quality, natural larch or cedar timber cladding with a planed finish. Timber cladding laid vertically and left to weather naturally. Proposed walls to the upper barn level to be finished externally in Met-Seam MS460 VM Zinc Plus, or similar approved, standing seam vertical cladding.

Head

103.51

Chy.

109.59

- 101.17

- 102.47WTop

108.21

WINDOWS/DOORS: Proposed window and doors to be light grey uPVC or powder coated aluminium framed, double glazed units. Windows to be traditional sliding sash units with external horns. Doors to the Living Area out onto the external balcony to be either sliding or bi-folding units. Window units to be set over minimum 150mm deep precast concrete sub-sills to be finished in sealer and good quality light grey masonry paint to match the window units.

104.77Head

Eaves

106.36

RAINWATER GOODS: New gutters to be ½ round light grey uPVC or powder coated aluminium gutters laid to fall on 200mm deep light grey uPVC or powder coated aluminium fascia boards. Gutters to be fitted with 64mm dia light grey uPVC or powder coated rainwater pipes to discharge into back inlet gullies. Gullies to be connected to new soakaways.

Typ

###### N

ROOF: Roof to be finished in dark blue/grey natural roof slates, or similar approved. Slates to be installed in strict accordance with the manufacturer’s instructions. Provide and fit dark blue/grey interlocking, angular, ridge tiles set on mortar bed. Provide and fit light grey uPVC or powder coated aluminium barge and soffit boards to all roof overhangs.

Grass

|EXISTING TIMBER SHED|
|---|

101.17

WTop

102.44

BALCONY: Edge of balcony to be fitted with ‘Q-Railing”, or similar approved, glass panel balcony system with top edge with bevelled glass finish. Panels set in proprietary stainless steel fascia brackets set over the top of precast concrete coping stones to be finished in sealer and good quality light grey masonry paint to match the window units.

101.14

- A-AA-A

- B-BB-B

Pillar

WTop

103.03

Visibility- 15m to road edge/26m to centre of road.

Tree

103.83Eaves

Eaves

103.74

Door blocked up Door blocked up

WTop

103.30

Gate

RWP

100.98

100.88Post

ROOF LIGHTS: Proposed roof lights to be fitted in the positions indicated on the elevations and to be 1180 x 940mm central pivot “Velux” roof light type GGL PK06, or similar approved, to be fitted with proprietary tray flashing surrounds. All work to be carried out in strict accordance with the manufacturer’s instructions.

103.69WTop

Steel posts and ﬂoor beam. 2,400 100 1,200 100 8,155 100 3,000 Steel posts and ﬂoor beam. Steel posts and ﬂoor beam.

102.32WTop

###### Corridor

3,670100930

Steel posts and ﬂoor beam.

Clks

- 100.91

- 100.92 100.89

100.84 100.75 100.62

2,3001002,300

PLANT ROOM

2,1501002,450

SHOWER

Steel posts and ﬂoor beam.

DRESSING

Floor

Wire

106.17

3,300

###### General Notes:

Steel posts and ﬂoor beam.

FIRE REGULATIONS: The proposed fire requirements for this type of residential development are covered under Approved Document B of the Building Regulations, including legislation for the installation of sprinkler systems and as such will be dealt with at the Building Regulation Submission Stage.

15m

Head

101.09

Conc

Telegraph pole to be re-sited across the road by MUA.

103.64

Ridge

4,700

105.80

Ridge

100.86Floor

RWP

Floor

UTILITY BEDROOM 2 ENSUITE

100.91

NOTE: This proposed drawing has been prepared to obtain statutory Planning approval only and should not be read as a full working drawing. The copyright of this drawing is the property of PenkethMillar Ltd and may not be reproduced without their permission. Written dimensions to be used in preference to scaled dimensions at all times.

The Plant Room outlet is built on the footprint of a previous lean-to extension built oﬀ the gable end of the main barn which has since been demolished with the north-west stone wall still remaining.

Conc

100.84

3,700 100

2,250 100 3,975 100 1,730 100 3,000

100.99DSill

101.12

Rubble

100.45

101.89

RWP

Rev:

New window New window New window Existing opening re-used. 100.87 100.81 100.90 100.88 100.60 100.66 100.63 100.86 100.65

102.80Head

Conc Conc

Purpose of Issue

1,040

PORCH

1,040 1,040

100.55 100.47

Bitmac

###### Planning

1,500

FWIC

100.36

WTop

100.37

102.94

23 West Quay Ramsey Isle of Man IM8 1DL

Grass

100.30

100.94

FWIC

RWP

2,225

100.87

100.41

Grass

Tel: 01624 813219 / 814178 Fax: 01624 816436 penkethmillar@manx.net www.penkethmillar.co.uk

REVISION A: 04/09/23

1. Existing timber shed added.

Stone

100.35

Stone

100.26

Foul drain to Bio-Disc

101.079003

|Client<br><br>Mr & Mrs G. Kinrade|
|---|

Foul drain to Bio-Disc Visibilty- 200m+ Existing vehicular access

101.03

Contract

100.25

100.08

100.97

Approved Ground Floor Plan & Elevations.

Proposed conversion of existing outbuilding into living/tourist accommodation at East Bretney Farm, Polly Road, Jurby East, IM7 3ES

Stone

100.34

100.05

100.46

100.05 Conc

100.66

Grass

100.10

Drawing Title

PROPOSED G.F. PLAN & ELEVATIONS

101.10

Drawing Information

Scales @ A1 Drawn by Drawing number Rev

Date

Ground Floor Plan 1:50

A

1:50, 1:100 DEC CPP 22 1651 22

.

General notes

|Ridge level 107.000|
|---|

|Ridge level 107.000|
|---|

- 1. This document and its design content is the copyright © property of Penketh Millar Ltd. and may not be reproduced in any way without the permission of Penketh Millar Ltd. It shall be read in conjunction with all other associated project information including models, speciﬁcations, schedules and related consultants documents.
- 2. Do not scale from documents, written dimensions to take preference at all times.
- 3. All dimensions & levels to be checked on site prior to construction or fabrication of any elements. Immediately report any discrepancies, errors or omissions on this document to this oﬃce. If in doubt ASK.
- 4. All structural timbers to be tanalised or similar approved treatment.
- 5. All Dimensions in this document are structural dimensions and do not allow for thickness of ﬁnishes.

Steel UB ridge purlin

Ex. ridge level 105.800

| |
|---|

31º

1,800 1,600

2,300 1,600

1,200

2,300 2,100

###### Utility Shower

WALLS: External cavity walls to the proposed extensions to be finished in untreated, good quality, natural larch or cedar timber cladding with a planed finish. Timber cladding laid vertically and left to weather naturally. Proposed walls to the upper barn level to be finished externally in Met-Seam MS460 VM Zinc Plus, or similar approved, standing seam vertical cladding.

WINDOWS/DOORS: Proposed window and doors to be light grey uPVC or powder coated aluminium framed, double glazed units. Windows to be traditional sliding sash units with external horns. Doors to the Living Area out onto the external balcony to be either sliding or bi-folding units. Window units to be set over minimum 150mm deep precast concrete sub-sills to be finished in sealer and good quality light grey masonry paint to match the window units.

BALCONY: Edge of balcony to be fitted with ‘Q-Railing”, or similar approved, glass panel balcony system with top edge with bevelled glass finish. Panels set in proprietary stainless steel fascia brackets set over the top of precast concrete coping stones to be finished in sealer and good quality light grey masonry paint to match the window units.

A-A Section 1:50 B-B Section 1:50

ROOF: Roof to be finished in dark blue/grey natural roof slates, or similar approved. Slates to be installed in strict accordance with the manufacturer’s instructions. Provide and fit dark blue/ grey interlocking, angular, ridge tiles set on mortar bed. Provide and fit light grey uPVC or powder coated aluminium barge and soffit boards to all roof overhangs.

3D Visual No 1

ROOF LIGHTS: Proposed roof lights to be fitted in the positions indicated on the elevations and to be 1180 x 940mm central pivot “Velux” roof light type GGL PK06, or similar approved, to be fitted with proprietary tray flashing surrounds. All work to be carried out in strict accordance with the manufacturer’s instructions.

|Ridge level 107.000|
|---|

| |
|---|

Steel UB ridge purlin. Steel UB ridge purlin. Steel UB ridge purlin. Steel UB ridge purlin. Steel UB ridge purlin. Steel UB ridge purlin Ex. ridge level 105.800 Ex. ridge level 105.800

|BA|BA|LCO|NY|
|---|---|---|---|
| |FFL 103.532|FFL 103.532| |

RAINWATER GOODS: New gutters to be ½ round light grey uPVC or powder coated aluminium gutters laid to fall on 200mm deep light grey uPVC or powder coated aluminium fascia boards. Gutters to be fitted with 64mm dia light grey uPVC or powder coated rainwater pipes to discharge into back inlet gullies. Gullies to be connected to new soakaways.

32º

KITCHEN AREA DINING AREA LIVING AREA BALCONY

2,3001,800

1,100

Steel posts and A-Frame Steel posts and A-Frame Steel posts and A-Frame Steel posts and A-Frame Steel posts and A-Frame Steel posts and A-Frame

BEDROOM 2

DRESSING MASTER BEDROOM

PLANT SHOWER ROOM

2,315

N

C-C Section 1:50

Section 1:50

B-BB-B

A-A

###### General Notes:

FIRE REGULATIONS: The proposed fire requirements for this type of residential development are covered under Approved Document B of the Building Regulations, including legislation for the installation of sprinkler systems and as such will be dealt with at the Building Regulation Submission Stage.

Roof light above Roof light above Roof light above Roof light above

Roof light above

Rev:

New staircase

Purpose of Issue

KITCHEN AREA

###### Planning

NOTE: This proposed drawing has been prepared to obtain statutory Planning approval only and should not be read as a full working drawing. The copyright of this drawing is the property of Penketh-Millar Ltd and may not be reproduced without their permission. Written dimensions to be used in preference to scaled dimensions at all times.

Steel posts and A-Frame Steel posts and A-Frame Steel posts and A-Frame Steel posts and A-Frame Steel posts and A-Frame

LIVING AREA

23 West Quay Ramsey Isle of Man IM8 1DL

Steel UB ridge purlin. Steel UB ridge purlin. Steel UB ridge purlin. Steel UB ridge purlin. Steel UB ridge purlin.

UP UP

BALCONY

Steel posts and A-Frame

Tel: 01624 813219 / 814178 Fax: 01624 816436 penkethmillar@manx.net www.penkethmillar.co.uk

BREAKFAST AREA

DINING AREA

|Client<br><br>Mr & Mrs G. Kinrade|
|---|

Wood burner & ﬂue. Roof light above Roof light above Roof light above Roof light above

Contract

Proposed conversion of existing outbuilding into living/tourist accommodation at East Bretney Farm, Polly Road, Jurby East, IM7 3ES

Approved First Floor Plan, Sections & 3D Model.

Drawing Title

PROPOSED F.F. PLAN & SECTIONS Drawing Information Scales @ A1 Drawn by Drawing number Rev

Date

First Floor Plan 1:50

1:50, 1:100 DEC CPP 22 1651 22

.

###### • P.A. No- 22/00182/B- Approved 19/02/22

Scrub

WTop

100.21

98.39

2.0 0.0 5.0 10.0 15.0

Scale = 1 : 100

Shrubs

HTop

103.20

98.72

Typ

98.51

98.53

99.08

98.04

remove existing shed

Thurlby Cottage

97.57

bbq

ﬁre

remove existing shed

Shed

97.65

Ridge

97.53

w

98.47

MASTER BEDROOM

cup'd

dressing

w

97.48

WTop

100.32

pantry

99.04

WTop

100.29

99.67

sh

WTop

en suite

coats/ shoes

GYM

Shrubs

en suite

sh

HTop

Typ

99.21

98.31

remove existing trees

HALL

w

KITCHEN

Grass

98.83

6,000

98.24

Grass

RWP

WTop

100.28

97.87

Head

100.12

Head

steps down

100.14

Conc

Eaves

Sill

100.75

99.10

steps down

FFL 98.33

HALL

Sill

remove existing tree

99.09

steps down

Tap

98.07

98.88

Grass

WTop

98.11

98.42

100.77

99.15

FAM BATH

demolish unsypathetic extensions

IC

Head

Grass

98.48

98.02

99.83

Conc

Flat

WTop

102.41

98.30

100.17

Head

99.32

99.97

sh

remove existing tree

Scrub

E-12

99.27

FFL 97.93

Ridge

Eaves

YG

Shrubs

UTILITY

101.48

Head

Sill98.81

99.95

RWP

Eaves

101.44

101.43

YG

Sill

99.29

Head

99.96

Grass

98.99

E-13

Conc

HOME OFFICE

demolish unsypathetic extensions

en suite

en suite

100.72

GU

Eaves

98.69

Ridge

100.50

DSill

102.68

99.03

GARAGE

Chy.

102.85

98.90 98.90

w

97.47

FFL 97.40

retain old link wall to thie veg

WTop

GUEST BEDROOM

Grass

dressing

Eaves

100.49

98.26

WTop

99.31

Head

remove existing tree

Ridge 99.85

102.58

Conc

DSill

new surface to driveway parking and turning hardstanding to be in a grey concrete tegular paver or a cobble set.

97.50

97.93

E-11

ST

98.84

98.15

Stone

97.68 97.68

Head100.74

Head

Outhouse

99.92

THIE VEG

98.25

Flat

Scrub

97.94

99.63

102.31

Sill99.96

97.82

Sill

98.57

retain old thie veg

E-14

Shrubs

WTop

97.79

97.78

SV

97.73

WTop

97.76 97.82

97.42

Stone

MT97.73

97.55

97.11

Bed

97.39 97.49

WTop

97.66

WTop

aco drain to existing entrance to prevent surface water spill onto carriageway.

Post

WTop

EP

97.07

96.85

97.69

Stay

Wire103.85

Gate

WTop

WTop

98.16

Wire103.56

Post

97.25

FFL 97.10

96.94

Wire

96.97 96.96

104.29

WTop

WTop

96.83

96.85 96.82

98.18

96.77

98.28

96.66

EXISTING DRIVEWAY ACCESS

97.30

97.85

96.63

Wire

101.87

Approved Ground Floor Plan.

Wire

97.27

104.24

B 43

98.20

EP

96.44

GROUND FLOOR PLAN 1:100

General notes

- 1. This document and its design content is the copyright © property of Penketh Millar Ltd. and may not be reproduced in any way without the permission of Penketh Millar Ltd. It shall be read in conjunction with all other associated project information including models, speciﬁcations, schedules and related consultants documents.
- 2. Do not scale from documents, written dimensions to take preference at all times.
- 3. All dimensions & levels to be checked on site prior to construction or fabrication of any elements. Immediately report any discrepancies, errors or omissions on this document to this oﬃce. If in doubt ASK.
- 4. All structural timbers to be tanalised or similar approved treatment.
- 5. All Dimensions in this document are structural dimensions and do not allow for thickness of ﬁnishes.

ELEVATION NOTES: COTTAGE WALLS: The existing cottage walls are to have the existing roughcast render removed along with the lower plinth and the walls restored to a white lime wash ﬁnish.

EXTENSION: New extension walls to be ﬁnished in a grey/ black dark stained cedar or scottish larch set vertically with shadow joint.

COTTAGE ROOF: The existing red proﬁled roof tile to be removed the roof pitch and ridge reduced and a thick reclaimed natural grey roof tile installed to the cottage roof.

EXTENSION: Extension roof to be in a metseam or similar metal standing seam roof in grey/black matt ﬁnish with hidden edge gutter system.

COTTAGE WINDOWS/DOORS: Remove the existing unsypathetic doors and windows and instal to the retained cottage timber sliding sash windows and timber door painted red.

EXTENSION: New windows and doors to extension element to be in a grey upvc or aluminium ﬁnish all with double glazed units. COTTAGE RAINWATER GOODS: Metal traditional style guttering and downpipe in a red to match the windows/doors. EXTENSION: Guttering to extension roof to be concealed to roof edge with downpipes behind the timber cladding. NOTE: THIS DRAWING HAS BEEN PRODUCED TO OBTAIN STATUTORY PLANNING APPROVAL ONLY AND SHOULD NOT BE READ AS A WORKING DRAWING.

Rev:

Purpose of Issue

###### Planning

23 West Quay Ramsey Isle of Man IM8 1DL

Tel: 01624 813219 / 814178 Fax: 01624 816436 penkethmillar@manx.net www.penkethmillar.co.uk

|Client<br><br>MR SMITH & MISS VERDON|
|---|

Contract

Drawing Title

PROPOSAL DRAWING Drawing Information Scales @ A1 Drawn by Drawing number

Date

1:100, 1:50 SEPT CM 21 1512 21

.

General notes

- 1. This document and its design content is the copyright © property of Penketh Millar Ltd. and may not be reproduced in any way without the permission of Penketh Millar Ltd. It shall be read in conjunction with all other associated project information including models, speciﬁcations, schedules and related consultants documents.
- 2. Do not scale from documents, written dimensions to take preference at all times.
- 3. All dimensions & levels to be checked on site prior to construction or fabrication of any elements. Immediately report any discrepancies, errors or omissions on this document to this oﬃce. If in doubt ASK.
- 4. All structural timbers to be tanalised or similar approved treatment.
- 5. All Dimensions in this document are structural dimensions and do not allow for thickness of ﬁnishes.

1 SOUTH ELEVATION 01 1:100 EAST ELEVATION 02 1:100 WEST ELEVATION 03 1:100 NORTH ELEVATION 04 1:100 Approved Elevations Purpose of Issue

23 West Quay Ramsey Isle of Man IM8 1DL

Tel: 01624 813219 / 814178 Fax: 01624 816436 penkethmillar@manx.net www.penkethmillar.co.uk

|Client<br><br>MR SMITH & MISS VERDON|
|---|

Contract

Drawing Title

ELEVATIONS

Drawing Information

Scales @ A1 Drawn by Drawing number Rev

Date

1:100, 1:185.78 SEPT CM 21 1512 21

.

#### 6. Access:

![A photograph showing the exterior of a white building with a paved driveway and a grassy area, set against a rural backdrop with green hills.](https://images.planningportal.im/2025/08/7098710.jpg)

The existing vehicle access oﬀ the main A1 Peel Road will be used to gain access to the proposed site. This is the main vehicle access to Rock Farm and visibility aﬀorded to this access is very good in both directions.

Once up at Rock Fram access to the proposed dwelling will be via the existing drive access located to the North-West of the main Farm House, which then leads to the lower ground ﬂoor level of the existing Old Mill Building and and existing rear lean-to outlet.

Existing vehicle access located to the rear North-West of the existing Farm House

Existing overgrown vehicle access looking North-West.

Existing overgrown vehicle access looking North-West, Old Mill Building visible in the background

Existing overgrown vehicle access looking North-West with the Old Mill Building on the right leading to the existing rear lean-to outlet.

![A photograph showing the exterior of a stone building with scaffolding, surrounded by overgrown vegetation and trees in a rural setting.](https://images.planningportal.im/2025/08/7098713.jpg)

#### 7. Services:

Both mains electricity and water are installed at the Old Mill Building.

The foul water drainage from the proposals would be provided by the installation of a “Klargester Bio-Disc” sewage treatment plant, see submitted Drainage Drawing number 25 1880/19 for further details, which will discharge to either on-site French drains or soakaway drainage system or alternatively a license obtained to discharge into the existing stream.

The surface water drainage system from the proposals would be provided by either the installation of on-site soakaways or alternatively connected direct to the existing Stream.

#### 8. Trees/Landscaping:

All existing mature trees are to remain in place to maintain a natural landscaped setting for the proposed dwelling. The Landscape Drawing number 25 1880/18 indicates all proposed landscape details, which includes lawned areas with wild/natural ornamental planting, the upgrading of the existing driveway to provide access down to the lower Garage and Car Port areas located in the existing Old Mill Building and the creation of front and rear Patio Areas.

#### 9. Bats & Birds:

Mitigation for bats and birds have been incorporated within the design of the dwelling, see Bat & Bird Details drawing number 25 1880/18 for further details. The proposals allow for the installation of 2No Bat Boxes. One located at the top of the South-West gable wall of the existing Old Mill Building and one located at the top of the South-East gable wall of the Bedroom extensions.

4No Bird Boxes are proposed with two erected in the existing trees located to the south of the existing Old Mill Building and two more located in the trees to the North-East.

#### 10. Sustainabilty:

The proposed dwelling would be designed having due regard to sustainability and reducing energy consumption. The three key issues of the proposed design would be high insulation levels, incorporating high quality double/triple glazed window/door units, complete airtightness of the proposed dwelling and a fully ﬁtted internal Mechanical Ventilation Heat Recovery system, (MVHR). A minimum SAP Rating of 93 will be required to be met by the proposals.

Heating the proposed dwelling would be either Air Source Heat Pump , (ASHP), or Ground Source Heat Pump, (GSHP). We have shown a typical location for the proposed ASHP on the proposed Ground Floor Plan. The proposed GSHP could be located in the garden area to the South-West of the proposed extensions and would be subject to a separate planing application

The ASHP or GSHP could be interconnected with PV solar panels, these could take the form of roof mounted units installed on the south facing roof slope of the existing Old Mill Building and/or the South-West roof slopes of the proposed Bedroom extension. Alternatively South facing ground mounted units could be located in the ﬁeld to the North-East of the proposed dwelling. Once again this would require a separate planning application.

---

*Data sourced from the Isle of Man public planning register under the [Isle of Man Open Government Licence](https://www.gov.im/about-this-site/open-government-licence/).*
*Canonical page: https://planningportal.im/a/33185-crosby-old-mill-building-conversion-extension/documents/1073758*